TuxedoApplication · Bea

CVE-2007-5576

MEDIUM · 6.8 CVSS v2.0 Published 2007-10-18
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
70/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
BEA Tuxedo 8.0 before RP392 and 8.1 before RP293, and WebLogic Enterprise 5.1 before RP174, echo the password in cleartext, which allows physically proximate attackers to obtain sensitive information via the (1) cnsbind, (2) cnsunbind, or (3) cnsls commands.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The vulnerability allows passwords to be echoed in cleartext when using the cnsbind, cnsunbind, or cnsls commands in BEA Tuxedo 8.0 before RP392, 8.1 before RP293, and WebLogic Enterprise 5.1 before RP174. Physically proximate attackers can obtain sensitive credential information by observing the displayed plaintext passwords.

MitigationApply the vendor-supplied patches: upgrade Tuxedo 8.0 to RP392 or later, Tuxedo 8.1 to RP293 or later, and WebLogic Enterprise 5.1 to RP174 or later. Alternatively, ensure these commands are only executed in physically secured environments.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
TuxedoApplication
Affected:= 8.0= 8.1
Weblogic IntegrationApplication
Affected:= 8.1= 9.2
Weblogic ServerApplication
Affected:= 5.1= 6.1= 7.0= 7.0.0.1= 8.1= 9.0= 9.1= 9.2
Weblogic WorkshopApplication
Affected:= 8.1
Weblogic PortalApplication
Affected:= 9.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Authentication
Single
Confidentiality
Complete
Integrity
Complete
Availability
Complete

AV:L/AC:L/Au:S/C:C/I:C/A:C

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed BEA Tuxedo version
    Run 'tpversion' or check the Tuxedo installation directory for version information. On Unix systems, check /tuxedo_version or the installation logs. On Windows, check the registry under HKEY_LOCAL_MACHINE\SOFTWARE\BEA\Tuxedo or the installation path.
    Affected if Version is 8.0 or 8.1 and the RP (rollup patch) level is below RP392 for 8.0 or RP293 for 8.1
  2. Identify installed WebLogic Enterprise version
    Check the WebLogic installation directory for version files, or run the WebLogic version command if available. Look for files named version.txt or similar in the BEA directory.
    Affected if Version is WebLogic Enterprise 5.1 and the RP level is below RP174
  3. Determine if cns commands are in use
    Search the system for the cnsbind, cnsunbind, or cnsls executables. These are typically found in the Tuxedo bin directory (for example, $TUXDIR/bin). Check if these commands are referenced in any scripts, cron jobs, or documentation.
    Affected if The cnsbind, cnsunbind, or cnsls commands are present and used in the environment
  4. Check if passwords are entered interactively with these commands
    Review any automation scripts or procedures that use cnsbind, cnsunbind, or cnsls. Observe whether these commands prompt for passwords interactively during normal operations.
    Affected if Users run cnsbind, cnsunbind, or cnsls interactively and passwords are entered at the command prompt

A user is affected if they run BEA Tuxedo 8.0 before RP392, Tuxedo 8.1 before RP293, or WebLogic Enterprise 5.1 before RP174, and use the cnsbind, cnsunbind, or cnsls commands which echo passwords in cleartext to the terminal.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply the vendor-supplied patches: upgrade Tuxedo 8.0 to RP392 or later, Tuxedo 8.1 to RP293 or later, and WebLogic Enterprise 5.1 to RP174 or later. Alternatively, ensure these commands are only executed in physically secured environments.

Fix this in Tuxedo Scoped from the published advisory
  • Consultation1.0 h
  • Implementation2.0 h
  • Testing2.0 h
  • Review / QA1.0 h
6.0 hours of engineering $1,040
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,664.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2007-5576 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2007-5576 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data