CVE-2010-5309
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedGE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceGE Healthcare CADStream Server contains a hardcoded default credential (admin/confirma) that allows unauthorized administrative access to the medical imaging workflow management system.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE dataall versionsCVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Authentication
- None
- Confidentiality
- Complete
- Integrity
- Complete
- Availability
- Complete
AV:N/AC:L/Au:N/C:C/I:C/A:C
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm CADStream Server installationInventory your medical imaging infrastructure to identify if GE Healthcare CADStream Server is deployed in your environment. Check with IT asset management systems or review installed medical imaging software on relevant servers.Affected if GE Healthcare CADStream Server is found in the environment
-
Verify default admin account statusCheck if the built-in 'admin' user account exists and is enabled on the CADStream Server. This may be visible in user management interfaces, directory services, or application configuration files.Affected if The admin account is present and active with the default username
-
Test default credential validityAttempt to authenticate to the CADStream administrative interface using the credentials admin/confirma. This may require access to the web management portal, terminal services, or application login endpoints.Affected if Authentication succeeds with admin/confirma, indicating the default password has not been changed
-
Review administrative access exposureDetermine if the CADStream administrative interface is accessible from network segments outside the trusted medical device network, including the internet or less-trusted VLANs.Affected if The administrative interface is exposed to untrusted networks without additional authentication controls
The environment is affected if GE Healthcare CADStream Server is deployed AND the default credential admin/confirma remains valid for authentication.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataImmediately change the default admin password to a strong, unique credential and implement password policy controls to prevent reuse of default credentials.
- Consultation2.0 h
- Implementation2.0 h
- Testing3.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,512.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2010-5309 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2010-5309 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data