Actively exploited in the wild. This CVE is on the CISA Known Exploited Vulnerabilities list — treat remediation as urgent. Federal remediation due by 6 May 2022.
AirosOperating system · Ui

CVE-2010-5330

CRITICAL · 9.8 CVSS v3.1 Published 2019-06-11
Fix available
A fix is available. Upgrade to 4.0.1 / 5.3.5 or later.
See remediation →
100/100
Remediation priority · Urgent
In the wild Public exploit Remotely reachable No privileges Zero-click Patch available

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
On certain Ubiquiti devices, Command Injection exists via a GET request to stainfo.cgi (aka Show AP info) because the ifname variable is not sanitized, as demonstrated by shell metacharacters. The fixed version is v4.0.1 for 802.11 ISP products, v5.3.5 for AirMax ISP products, and v5.4.5 for AirSync firmware. For example, Nanostation5 (Air OS) is affected.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Command injection vulnerability in Ubiquiti device web interface (stainfo.cgi) allows remote attackers to execute arbitrary shell commands via unsanitized ifname parameter containing shell metacharacters in a GET request.

MitigationUpgrade affected Ubiquiti devices to the fixed firmware versions (v4.0.1 for 802.11 ISP, v5.3.5 for AirMax ISP, v5.4.5 for AirSync) or restrict network access to the management interface to prevent external exploitation.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
AirosOperating system
Affected:< 4.0.1>= 4.0.2, < 5.3.5>= 5.3.6, < 5.4.5

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the Ubiquiti device model
    Access the device web interface or use SSH to run 'cat /proc/cpuinfo' or check the management UI for the device model name (e.g., Nanostation5)
    Affected if The device is a Ubiquiti Nanostation5 or other model running AirOS firmware
  2. Check the AirOS firmware version
    Log into the device web UI (System tab) or use SSH to run 'cat /etc/version' to retrieve the firmware version number
    Affected if The firmware version is < 4.0.1 OR (>= 4.0.2 AND < 5.3.5) OR (>= 5.3.6 AND < 5.4.5)
  3. Verify if the stainfo.cgi web interface is accessible
    Attempt to access 'http://<device_ip>//cgi-bin/stainfo.cgi' from a network-connected host. A successful HTTP 200 response indicates the interface is enabled
    Affected if The stainfo.cgi endpoint returns a valid response (the web management interface is enabled and reachable)
  4. Confirm remote management is enabled
    Check the device web UI under System > Site Settings or use SSH to inspect configuration files in /etc/persistent/ to see if remote web access is permitted
    Affected if Remote web management is enabled and the device is accessible from an attacker's network position

A user is affected if they have a Ubiquiti device (e.g., Nanostation5) running AirOS firmware versions < 4.0.1, 4.0.2 to < 5.3.5, or 5.3.6 to < 5.4.5, with the stainfo.cgi web interface exposed and remote management enabled.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 4.0.1 / 5.3.5 / 5.4.5 or later
Fixed in 4.0.15.3.55.4.5
Vendor patch community.ubnt.com →
Interim mitigation

Upgrade affected Ubiquiti devices to the fixed firmware versions (v4.0.1 for 802.11 ISP, v5.3.5 for AirMax ISP, v5.4.5 for AirSync) or restrict network access to the management interface to prevent external exploitation.

Recommended fix High confidence

AirOS v4.0.1 (802.11 ISP products), v5.3.5 (AirMax ISP products), or v5.4.5 (AirSync firmware)

  1. 1. Identify the Ubiquiti device model and current AirOS firmware version via the web UI or SSH (cat /etc/version)
  2. 2. Determine the product type: 802.11 ISP products (e.g., Nanostation2, Nanostation5), AirMax ISP products, or AirSync firmware
  3. 3. For 802.11 ISP products: upgrade to AirOS v4.0.1 or later
  4. 4. For AirMax ISP products: upgrade to v5.3.5 or later (or preferably latest 5.x release)
  5. 5. For AirSync firmware: upgrade to v5.4.5 or later
  6. 6. Download the appropriate firmware from the official Ubiquiti Downloads portal (https://www.ui.com/download)
  7. 7. Access the device's web interface, navigate to the System or Maintenance section
  8. 8. Upload the firmware file and allow the device to reboot
Caveat Firmware upgrades on embedded devices may reset configuration; backup settings before upgrading. Some legacy devices may have limited upgrade paths.

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Airos Exploited in the wild — priority engagement
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing2.0 h
  • Review / QA1.0 h
9.0 hours of engineering $1,600
Get it fixed fast

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,560.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2010-5330 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2010-5330 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data