CWE-294Weakness · CWE-294

CVE-2011-20002

HIGH · 7.4 CVSS v3.1 Published 2025-10-14
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
83/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The SIMATIC S7-1200 CPU V1 and V2 families contain a capture-replay vulnerability in their communication protocol with engineering software. An on-path attacker can intercept and record commands during normal engineering sessions, then replay those recorded commands later to manipulate the controller (e.g., switching to STOP mode). The S7 communication protocol lacks proper replay protection or session authentication, making the attack effective even when passwords are configured.

MitigationUpdate SIMATIC S7-1200 CPU firmware to version V2.0.2 or later to remediate this vulnerability. Network segmentation and monitoring for anomalous traffic between engineering workstations and controllers can provide additional defense-in-depth.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify SIMATIC S7-1200 CPU in the environment
    Inventory network-connected devices and identify any SIMATIC S7-1200 PLCs. Check device nameplates, HMIs, or engineering software project files for S7-1200 CPU models.
    Affected if A SIMATIC S7-1200 CPU V1 or V2 model is present in the environment.
  2. Determine the firmware version of the S7-1200 CPU
    Connect to the controller via TIA Portal or use the 'Device Information' web page if available, or query the device via S7 communication to read the firmware version field. Compare the version against the affected range (V1.x or V2.x prior to V2.0.2).
    Affected if The firmware version is V1.x or V2.x (versions prior to V2.0.2).
  3. Verify S7 communication protocol is enabled
    Check the controller's protection settings in TIA Portal under 'Protection' > 'Access Protection' or inspect the device configuration for S7 communication (ISO-TCP/TCP native) enabled ports (102/TCP).
    Affected if S7 communication is enabled and the controller is accessible over the network.
  4. Check network exposure of engineering access
    Review firewall rules, VLAN configurations, and network diagrams to determine if the S7-1200 is accessible from the engineering workstation network or exposed to untrusted segments.
    Affected if The S7-1200 is reachable from network segments other than a trusted engineering workstation network.

The environment is affected if a SIMATIC S7-1200 CPU with firmware V1.x or V2.x (prior to V2.0.2) has S7 communication enabled and is accessible on the network.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Update SIMATIC S7-1200 CPU firmware to version V2.0.2 or later to remediate this vulnerability. Network segmentation and monitoring for anomalous traffic between engineering workstations and controllers can provide additional defense-in-depth.

Recommended fix High confidence

SIMATIC S7-1200 CPU V1/V2 family firmware V2.0.2 or later

  1. 1. Identify the current firmware version of the SIMATIC S7-1200 CPU by connecting via TIA Portal or checking the controller properties
  2. 2. Navigate to the Siemens Industry Online Support website and download the firmware update for SIMATIC S7-1200 CPU V1/V2 family to version V2.0.2 or later
  3. 3. Create a complete backup of the current controller project and configuration using TIA Portal
  4. 4. Establish a direct Ethernet connection between the engineering workstation and the controller for firmware update
  5. 5. Using TIA Portal or the appropriate firmware update tool, upload and install firmware version V2.0.2 or later onto the controller
  6. 6. After the firmware update completes, verify the new version is installed by checking the controller's firmware information
  7. 7. Restore the controller project from backup and verify all configurations are intact
  8. 8. Test controller functionality to ensure normal operation, including communication with engineering software
Caveat Firmware updates may temporarily disrupt controller operation; test in a non-production environment first and ensure project backup before upgrading

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation6.0 h
  • Implementation8.0 h
  • Testing8.0 h
  • Review / QA4.0 h
26.0 hours of engineering $4,560
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,296.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2011-20002 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2011-20002 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data