LifelineOperating system · Emc

CVE-2012-2283

MEDIUM · 5.5 CVSS v2.0 Published 2012-08-16
Fix available
A fix is available. Upgrade to 3.2.3.15290 or later.
See remediation →
61/100
Remediation priority · Elevated
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The Iomega Home Media Network Hard Drive with EMC Lifeline firmware before 2.104, Home Media Network Hard Drive Cloud Edition with EMC Lifeline firmware before 3.2.3.15290, iConnect with EMC Lifeline firmware before 2.5.26.18966, and StorCenter with EMC Lifeline firmware before 2.0.18.23122, 2.1.x before 2.1.42.18967, and 3.x before 3.2.3.15290 allow remote authenticated users to read or modify data on arbitrary remote shares via unspecified vectors.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This is a broken access control vulnerability in EMC Lifeline firmware used by multiple Iomega network-attached storage (NAS) devices. The flaw allows any remote authenticated user to read or modify data on arbitrary remote shares, bypassing intended access controls between share permissions and user authentication.

MitigationUpdate EMC Lifeline firmware to the patched versions (2.104 for Home Media HD, 3.2.3.15290 for Cloud Edition/StorCenter 3.x, 2.5.26.18966 for iConnect, or 2.0.18.23122/2.1.42.18967 for StorCenter 2.x). If immediate patching is not feasible, restrict network access to these devices and review user/share permission mappings.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
LifelineOperating system
Affected:<= 2.103<= 3.2.3.15289<= 2.5.26.18965<= 2.0.18.23121>= 2.1.0, <= 2.1.42.18966>= 3.0, < 3.2.3.15290= 23.2.3.15289
Home Media Network Hard DriveHardware / appliance
Affected:all versions
IconnectHardware / appliance
Affected:all versions
StorcenterHardware / appliance
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Authentication
Single
Confidentiality
Partial
Integrity
Partial
Availability
None

AV:N/AC:L/Au:S/C:P/I:P/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify device model and firmware type
    Access the device admin interface or check the system information page to determine if the device is an Iomega NAS (Home Media Network Hard Drive, Iconnect, or Storcenter) or runs EMC Lifeline firmware.
    Affected if The device is an Iomega Home Media Network Hard Drive, Iomega Iconnect, Iomega Storcenter, or any device running EMC Lifeline firmware.
  2. Determine installed firmware version
    Navigate to the device admin panel, typically at the device's IP address, and locate the firmware version information (usually under System, Settings, or About). Alternatively, check the command line interface if accessible.
    Affected if For EMC Lifeline: version is 2.103 or lower; 3.2.3.15289 or lower; 2.5.26.18965 or lower; 2.0.18.23121 or lower; between 2.1.0 and 2.1.42.18966 inclusive; between 3.0 and 3.2.3.15289 inclusive; or exactly 23.2.3.15289. For Iomega devices: if the device model is Home Media Network Hard Drive, Iconnec
  3. Verify remote share access is configured
    Check the device share configuration settings in the admin interface to see if any network shares are exposed and accessible to remote users.
    Affected if Network shares are created and accessible to remote users, which is required for the vulnerability to be exploitable.
  4. Confirm user authentication is enabled
    Verify that the device has user accounts configured and authentication is required for accessing shares.
    Affected if User authentication is enabled on the device, as the flaw allows any remote authenticated user to bypass share access controls.

A user is affected if their device is an Iomega Home Media Network Hard Drive, Iomega Iconnect, or Iomega Storcenter (all versions), or runs EMC Lifeline firmware matching the vulnerable version ranges listed, and has remote shares accessible to authenticated users.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 3.2.3.15290 or later
Fixed in 3.2.3.15290
Interim mitigation

Update EMC Lifeline firmware to the patched versions (2.104 for Home Media HD, 3.2.3.15290 for Cloud Edition/StorCenter 3.x, 2.5.26.18966 for iConnect, or 2.0.18.23122/2.1.42.18967 for StorCenter 2.x). If immediate patching is not feasible, restrict network access to these devices and review user/share permission mappings.

Fix this in Lifeline Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2012-2283 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2012-2283 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm