Eos Box Photovoltaic Monitoring System FirmwareOperating system · Carlosgavazzi

CVE-2012-6428

HIGH · 10.0 CVSS v2.0 Published 2012-12-23
Fix available
A fix is available. Upgrade to after 1.0.0 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The Carlo Gavazzi EOS-Box stores hard-coded passwords in the PHP file of the device. By using the hard-coded passwords, attackers can log into the device with administrative privileges. This could allow the attacker to have unauthorized access.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The Carlo Gavazzi EOS-Box stores hard-coded passwords directly in PHP files on the device firmware. Attackers who obtain these credentials (which are static and cannot be changed by users) can authenticate to the device's web interface with administrative privileges, achieving full unauthorized control.

MitigationApply any available firmware updates to remove hard-coded credentials; immediately change default passwords if user-settable; network-segment or firewall the device to limit exposure; disable remote management if not required.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Eos Box Photovoltaic Monitoring System FirmwareOperating system
Affected:<= 1.0.0
Eos Box Photovoltaic Monitoring SystemHardware / appliance
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Authentication
None
Confidentiality
Complete
Integrity
Complete
Availability
Complete

AV:N/AC:L/Au:N/C:C/I:C/A:C

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Carlo Gavazzi EOS-Box device on the network
    Perform a network scan for devices responding on HTTP (port 80) or HTTPS (port 443) and look for web page titles or favicons mentioning 'Carlo Gavazzi', 'EOS-Box', or 'Photovoltaic Monitoring'. Check device MAC OUI for manufacturer signatures if available.
    Affected if A Carlo Gavazzi EOS-Box photovoltaic monitoring device is present on the network.
  2. Determine the firmware version
    Access the device web interface and navigate to the System Information, Status, or About page typically found in admin/settings menus. Alternatively, if you have extracted the firmware binary, search for version strings using binwalk, strings, or a hex editor.
    Affected if The firmware version is 1.0.0 or lower, or the device is confirmed to be an EOS-Box Photovoltaic Monitoring System of any version.
  3. Extract and inspect firmware for PHP files
    If you can obtain the firmware file (from manufacturer downloads or device extraction), decompress it and search for .php files. Use grep or strings to search within PHP files for patterns like 'password', 'passwd', or hardcoded string literals.
    Affected if PHP files in the firmware contain hardcoded password strings or credentials that are not derived from user configuration.
  4. Verify credentials are user-changeable
    Attempt to locate password change functionality in the device web interface under Admin, Settings, or User Management sections. Check if the interface allows changing the administrative password or if credentials remain static.
    Affected if The device does not provide a mechanism to change the administrative password, or the same hardcoded credentials persist after attempting to change them.
  5. Test for unauthorized admin access
    Attempt to authenticate to the device web interface using known default credentials or credentials extracted from firmware analysis. Verify if authentication succeeds with administrative privileges.
    Affected if Authentication succeeds with hardcoded credentials giving full administrative control without any user-set password.

A Carlo Gavazzi EOS-Box device with firmware version 1.0.0 or lower, or any version of the EOS-Box Photovoltaic Monitoring System where the administrative password cannot be changed and is hardcoded in PHP files, is affected by CVE-2012-6428.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 1.0.0
Interim mitigation

Apply any available firmware updates to remove hard-coded credentials; immediately change default passwords if user-settable; network-segment or firewall the device to limit exposure; disable remote management if not required.

Fix this in Eos Box Photovoltaic Monitoring System Firmware Scoped from the published advisory
  • Consultation3.0 h
  • Implementation4.0 h
  • Testing2.0 h
  • Review / QA1.0 h
10.0 hours of engineering $1,800
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,880.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2012-6428 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2012-6428 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data