Scada Web ServerApplication · Ininet Solutions

CVE-2015-1001

HIGH · 10.0 CVSS v2.0 Published 2015-10-25
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Multiple stack-based buffer overflows in IniNet embeddedWebServer (aka eWebServer) before 2.02 allow remote attackers to execute arbitrary code via a long field in an HTTP request.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Multiple stack-based buffer overflow vulnerabilities exist in IniNet embeddedWebServer (eWebServer) versions prior to 2.02. The vulnerabilities are triggered by sending HTTP requests containing overly long field values, which overflow stack-based buffers and allow remote attackers to execute arbitrary code.

MitigationUpgrade embeddedWebServer to version 2.02 or later. If the product is no longer supported, migrate to an actively maintained web server solution and implement network segmentation to limit exposure to untrusted networks.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Scada Web ServerApplication
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Authentication
None
Confidentiality
Complete
Integrity
Complete
Availability
Complete

AV:N/AC:L/Au:N/C:C/I:C/A:C

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if IniNet embeddedWebServer is installed
    Search for web server processes or services on the system. Check common installation paths for web servers in SCADA/ICS environments. Look for service names containing 'eweb', 'inetweb', 'ininet', or 'scada web'.
    Affected if The software is present on the system and runs as a service or process
  2. Determine the installed version of embeddedWebServer
    Check the executable version information. Look for version metadata in the web server binary or check any version file in the installation directory. Compare your version against the 2.02 threshold.
    Affected if The installed version is lower than 2.02 or the version cannot be determined (all versions prior to 2.02 are affected)
  3. Verify the HTTP service is exposed and listening
    Use netstat or similar tools to check if the web server is listening on any HTTP port (common ports include 80, 8080, 443). Confirm the service is reachable over the network.
    Affected if The HTTP service is listening and accessible from network paths
  4. Check for unusually long HTTP request handling
    Review any available access logs or network captures for HTTP requests with excessively long header values, cookie values, or URI parameters that may indicate exploitation attempts.
    Affected if Logs show long field values or potential exploitation activity
  5. Assess network exposure of the web server
    Determine if the SCADA/web server is directly accessible from untrusted networks. Check firewall rules and network segmentation around the ICS environment.
    Affected if The server is exposed to untrusted networks without proper network segmentation

The environment is affected if IniNet embeddedWebServer is running with a version below 2.02 and is network-accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade embeddedWebServer to version 2.02 or later. If the product is no longer supported, migrate to an actively maintained web server solution and implement network segmentation to limit exposure to untrusted networks.

Recommended fix Moderate confidence

2.02

  1. 1. Identify the current version of IniNet embeddedWebServer (eWebServer) installed in your environment
  2. 2. Obtain the fixed version 2.02 or later from the vendor (IniNet)
  3. 3. Before upgrading, backup all configuration files and web content
  4. 4. Stop the Scada Web Server service
  5. 5. Install version 2.02 of embeddedWebServer
  6. 6. Restore configuration files from backup if needed
  7. 7. Restart the Scada Web Server service
  8. 8. Verify the server is running and responsive

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Scada Web Server Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing4.0 h
  • Review / QA2.0 h
12.0 hours of engineering $2,080
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,328.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2015-1001 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2015-1001 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data