CVE-2015-4821
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedUnspecified vulnerability in the Integrated Lights Out Manager (ILOM) component in Oracle Sun Systems Products Suite 3.0, 3.1, and 3.2 allows remote attackers to affect confidentiality, integrity, and availability via unknown vectors related to Web.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceA remote code execution vulnerability in Oracle Sun ILOM (Integrated Lights Out Manager) web interface allows attackers to impact confidentiality, integrity, and availability. The unspecified web-related vulnerability affects ILOM versions 3.0, 3.1, and 3.2 with CVSS 9.3 indicating critical severity requiring no authentication.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 3.0= 3.1= 3.2CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- M
- Authentication
- None
- Confidentiality
- Complete
- Integrity
- Complete
- Availability
- Complete
AV:N/AC:M/Au:N/C:C/I:C/A:C
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify Oracle Sun ILOM installationAccess the server's BMC/ILOM interface via IPMI or SSH (typically at the BMC IP address). Confirm the product is Oracle Sun Integrated Lights Out Manager (ILOM).Affected if The managed device runs Oracle Sun ILOM firmware
-
Check ILOM firmware versionFrom the ILOM web interface, navigate to the About or Firmware section to view the installed version. Alternatively, use the ILOM CLI command: version or show /system/firmware to retrieve the firmware version.Affected if The installed version is 3.0, 3.1, or 3.2
-
Verify web interface is enabledIn the ILOM web interface, navigate to ILOM Administration > Web Server or Settings > Services to confirm if the HTTP/HTTPS web interface is enabled. From CLI, check using: show /SP/web or show /SP/webSSL.Affected if The ILOM web interface (HTTP or HTTPS) is accessible and enabled
If the system runs Oracle Sun ILOM versions 3.0, 3.1, or 3.2 with the web interface enabled, the environment is affected by CVE-2015-4821.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpgrade ILOM firmware to patched versions beyond 3.2; if patching is not immediately feasible, restrict web interface access to trusted networks via firewall rules and disable ILOM web services if not required.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2015-4821 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2015-4821 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm