CWE-257Weakness · CWE-257

CVE-2016-15058

HIGH · 8.1 CVSS v3.1 Published 2026-04-03
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
86/100
Remediation priority · High
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Hirschmann HiLCOS Classic Platform switches Classic L2E, L2P, L3E, L3P versions prior to 09.0.06 and Classic L2B prior to 05.3.07 contain a credential exposure vulnerability where user passwords are synchronized with SNMPv1/v2 community strings and transmitted in plaintext when the feature is enabled. Attackers with local network access can sniff SNMP traffic or extract configuration data to recover plaintext credentials and gain unauthorized administrative access to the switches.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Hirschmann HiLCOS Classic Platform switches contain a credential exposure vulnerability where user passwords are synchronized with SNMPv1/v2 community strings and transmitted in plaintext. Attackers with local network access can sniff SNMP traffic or extract configuration data to recover these plaintext credentials and gain administrative access.

MitigationDisable the password-to-SNMP community synchronization feature and upgrade firmware to version 09.0.06 (for L2E/L2P/L3E/L3P) or 05.3.07 (for L2B). If SNMP is required, migrate to SNMPv3 with authentication and encryption.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the HiLCOS variant and firmware version
    Access the switch management interface (web GUI or CLI) and navigate to System > Software or use the 'show version' command in CLI to determine if the device runs HiLCOS Classic and note the exact version number.
    Affected if The device runs HiLCOS Classic and the version is prior to 09.0.06 for L2E/L2P/L3E/L3P, or prior to 05.3.07 for L2B.
  2. Verify SNMP is enabled
    In the web GUI, go to SNMP > General Settings, or in CLI use 'show snmp' to check if SNMP is configured and active on the device.
    Affected if SNMP is enabled on the switch.
  3. Confirm the SNMP version in use
    In SNMP settings, check whether the device is configured to use SNMPv1, SNMPv2c, or SNMPv3. SNMPv3 provides authentication and encryption.
    Affected if The device uses SNMPv1 or SNMPv2c (SNMPv1/v2).
  4. Check for password-to-community synchronization
    In the web GUI, look under SNMP > Community Strings or SNMP > Security settings for an option linking user passwords to SNMP community strings. In CLI, look for 'snmp sync' or similar commands.
    Affected if The password-to-community synchronization feature is enabled, causing user passwords to be used as SNMP community strings.
  5. Inspect configuration for plaintext credentials
    Export the device configuration file (via backup or TFTP) and search for SNMP community string entries. Compare these to user account passwords if the sync feature is active.
    Affected if SNMP community strings match user account passwords, indicating they are synchronized.

The environment is affected if the switch runs a vulnerable HiLCOS Classic version with SNMP enabled using v1/v2 and has the password-to-community synchronization feature active.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Disable the password-to-SNMP community synchronization feature and upgrade firmware to version 09.0.06 (for L2E/L2P/L3E/L3P) or 05.3.07 (for L2B). If SNMP is required, migrate to SNMPv3 with authentication and encryption.

Recommended fix High confidence

Classic L2E/L2P/L3E/L3P: version 09.0.06 or later; Classic L2B: version 05.3.07 or later

  1. Identify the specific Hirschmann HiLCOS Classic Platform switch model (L2E, L2P, L3E, L3P, or L2B)
  2. Check the current firmware version by accessing the switch management interface
  3. For Classic L2E, L2P, L3E, or L3P models: upgrade to firmware version 09.0.06 or later
  4. For Classic L2B models: upgrade to firmware version 05.3.07 or later
  5. After upgrading, access the switch configuration and verify the SNMP password synchronization feature is disabled
  6. Change all administrative passwords that may have been exposed during the vulnerability window
  7. Enable SNMPv3 with authentication and encryption instead of SNMPv1/v2 if SNMP access is required
Caveat Firmware upgrades on industrial network equipment may require configuration backup and downtime window; verify compatibility with existing network setup before upgrading

Generated from the published advisory — verify against the referenced sources before acting.

Have this fixed Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing8.0 h
  • Review / QA4.0 h
30.0 hours of engineering $5,280
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,448.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2016-15058 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2016-15058 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data