Oncell G3001 FirmwareOperating system · Moxa

CVE-2016-5799

CRITICAL · 9.8 CVSS v3.0 Published 2016-08-24
Fix available
A fix is available. Upgrade to after 2.7 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 do not properly restrict authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Moxa OnCell G3100V2 (before v2.8) and G3111/G3151/G3211/G3251 (before v1.7) industrial cellular gateways contain a flaw in their authentication mechanism that fails to properly restrict or limit login attempts. This allows remote attackers to conduct brute-force attacks to guess credentials and gain unauthorized administrative access to the device.

MitigationUpgrade firmware to version 2.8 (G3100V2) or 1.7+ (G3111/G3151/G3211/G3251). If immediate patching is not feasible, implement network segmentation, firewall rules to limit exposure, and monitor for brute-force attack patterns.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Oncell G3001 FirmwareOperating system
Affected:<= 1.6
Oncell G3100v2 FirmwareOperating system
Affected:<= 2.7

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the exact device model
    Check the device label, web interface header, or use SNMP (snmpwalk on OID 1.3.6.1.4.1.8691.7.1.1.1.0 for product name)
    Affected if Device is not a Moxa OnCell G3001 or G3100V2 (this CVE does not apply)
  2. Check the installed firmware version
    Access the device web interface and navigate to System > Firmware Update, or use CLI command 'show system info', or query SNMP OID 1.3.6.1.4.1.8691.7.1.1.2.0 for firmware version
    Affected if Firmware version is 1.6 or lower for G3001, or 2.7 or lower for G3100V2
  3. Verify login attempt configuration
    Log into the device web interface and navigate to Security > Authentication or Account settings. Look for a 'Login Attempt Limit', 'Max Login Failures', or 'Account Lockout' setting
    Affected if No login attempt limit is configured, or the limit is set to 'unlimited' or '0', or the setting is missing entirely
  4. Review authentication logs for brute-force evidence
    Access device logs via System > Log or CLI 'show log'. Search for repeated failed login attempts from the same source IP
    Affected if Logs show many failed login attempts indicating the device has been exposed to brute-force attacks

The device is affected if it is a Moxa OnCell G3001 with firmware <= 1.6 or G3100V2 with firmware <= 2.7 and the login attempt limit feature is not enabled or is missing.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to a release after 2.7
Interim mitigation

Upgrade firmware to version 2.8 (G3100V2) or 1.7+ (G3111/G3151/G3211/G3251). If immediate patching is not feasible, implement network segmentation, firewall rules to limit exposure, and monitor for brute-force attack patterns.

Recommended fix High confidence

OnCell G3100v2: firmware >= 2.8 | OnCell G3111/G3151/G3211/G3251: firmware >= 1.7 | OnCell G3001: firmware >= 1.7

  1. 1. Identify the exact model of Moxa OnCell device (G3001, G3100v2, G3111, G3151, G3211, or G3251)
  2. 2. Determine the current firmware version by accessing the device's web interface or using Moxa administration tools
  3. 3. For OnCell G3100v2: If firmware version is <= 2.7, download firmware version 2.8 or later from Moxa's official support website
  4. 4. For OnCell G3111/G3151/G3211/G3251: If firmware version is <= 1.6, download firmware version 1.7 or later from Moxa's official support website
  5. 5. For OnCell G3001: If firmware version is <= 1.6, download firmware version 1.7 or later from Moxa's official support website
  6. 6. Back up the current device configuration before performing firmware upgrade
  7. 7. Upload the new firmware via the device's web interface or using Moxa's firmware update utility
  8. 8. After upgrade, verify the new firmware version is installed
Caveat Review Moxa release notes for version 2.8 (G3100v2) and version 1.7 (G3001/G3111/G3151/G3211/G3251) to check for any configuration or feature changes that may affect existing deployments

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Oncell G3001 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation2.0 h
  • Testing2.0 h
  • Review / QA1.0 h
7.0 hours of engineering $1,240
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,984.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2016-5799 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2016-5799 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data