Network AdvisorApplication · Brocade

CVE-2016-8207

HIGH · 7.5 CVSS v3.0 Published 2017-01-14
Fix available
A fix is available. Upgrade to after 14.0.2 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A Directory Traversal vulnerability in CliMonitorReportServlet in the Brocade Network Advisor versions released prior to and including 14.0.2 could allow remote attackers to read arbitrary files including files with sensitive user information.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A directory traversal vulnerability exists in CliMonitorReportServlet of Brocade Network Advisor (versions prior to and including 14.0.2) that allows remote attackers to read arbitrary files on the system by manipulating file paths with traversal sequences (such as ../), potentially exposing sensitive user information.

MitigationUpgrade Brocade Network Advisor to a version beyond 14.0.2. Additionally, implement strict input validation on file path parameters and enforce proper access controls on the servlet to prevent unauthorized file access.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Network AdvisorApplication
Affected:<= 14.0.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if Brocade Network Advisor is installed
    Look for the Brocade Network Advisor installation directory (commonly in /opt/brocade or C:\Program Files\Brocade on Windows). Check for running processes named 'BrocadeNetworkAdvisor' or related services.
    Affected if Brocade Network Advisor software is found running or installed on the system.
  2. Determine the installed version of Brocade Network Advisor
    Check the application's version. On Windows, right-click the executable and view Properties > Details for version info. Alternatively, look for a version.txt or README file in the installation directory, or query the application via its web interface or CLI if available.
    Affected if The installed version is 14.0.2 or any version prior to 14.0.2.
  3. Verify the CliMonitorReportServlet is accessible
    Check if the web interface for Brocade Network Advisor is exposed. The vulnerable servlet is typically accessed at a URL path containing 'CliMonitorReportServlet'. Attempt to access it via the application's web port (default is often 8080).
    Affected if The CliMonitorReportServlet is reachable over the network without authentication.
  4. Check for directory traversal attempts in access logs
    Review the application and web server access logs for the CliMonitorReportServlet. Look for log entries containing '../' sequences or unusual file path patterns in requests to this servlet.
    Affected if Log entries show '../' traversal sequences or requests for system files (like /etc/passwd or Windows system files) targeting the CliMonitorReportServlet.
  5. Inspect for recently accessed sensitive files
    Review system files that may have been accessed via traversal, such as configuration files, password stores, or user data directories on the host. Check file system audit logs for unexpected read access from the application process.
    Affected if Sensitive configuration files, credentials, or user data files show unexpected access timestamps or were accessed by the Brocade Network Advisor process.

The environment is affected if Brocade Network Advisor version 14.0.2 or earlier is installed and the CliMonitorReportServlet web interface is accessible, enabling potential unauthorized file access via directory traversal.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 14.0.2
Interim mitigation

Upgrade Brocade Network Advisor to a version beyond 14.0.2. Additionally, implement strict input validation on file path parameters and enforce proper access controls on the servlet to prevent unauthorized file access.

Fix this in Network Advisor Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2016-8207 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2016-8207 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm