NVD · uneditedA Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version PLAT 7.3 (E0504) was found. The problem was resolved in HPE Intelligent Management Center PLAT v7.3 (E0506) or any subsequent version.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceA Remote Code Execution vulnerability exists in HPE Intelligent Management Center PLAT version 7.3 (E0504). The vulnerability is exploitable remotely with low complexity and no authentication required, allowing an attacker to execute arbitrary code on the affected system.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 7.3CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Verify HPE Intelligent Management Center PLAT is installedCheck for the presence of HPE iMC PLAT in the system. Common installation paths include C:\Program Files\HPE\iMC\ or /opt/hp/imc/. Look for the imc.exe process or the 'iMC PLAT' service in Windows Services or Linux service listings.Affected if The product is not installed on the system.
-
Identify the installed version of iMC PLATLocate the version information file or check the product properties. In Windows, right-click the installed application shortcut and select Properties, or check the version info of the imc.exe binary. On Linux, run: find /opt -name 'version*' -o -name 'build*' 2>/dev/nullAffected if Unable to determine the version number from the installation.
-
Confirm the exact version matches CVE-affected releaseCompare your identified version against the affected version: 7.3 (E0504). The CVE explicitly states version 7.3 (E0504) is affected. Any other subversion or build of 7.3 may or may not be vulnerable - verify the E0504 build number specifically.Affected if The installed version is exactly 7.3 (E0504).
A system is affected only if HPE Intelligent Management Center PLAT version 7.3 (E0504) is installed and running.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpgrade HPE Intelligent Management Center PLAT to version 7.3 (E0506) or any subsequent version to remediate this vulnerability.
- Consultation2.0 h
- Implementation4.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,560.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2017-12522 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2017-12522 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data