Stdu ViewerApplication · Stdutility

CVE-2017-14300

HIGH · 7.8 CVSS v3.0 Published 2017-09-11
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
80/100
Remediation priority · High
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
STDU Viewer 1.6.375 allows attackers to execute arbitrary code or cause a denial of service via a crafted .jb2 file, related to "Data from Faulting Address controls subsequent Write Address starting at STDUJBIG2File!DllGetClassObject+0x0000000000004479."

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

STDU Viewer 1.6.375 contains a memory corruption vulnerability when parsing specially crafted JB2 image files. The vulnerability is a write-what-where condition where data from a faulting address controls a subsequent write address, allowing attackers to overwrite arbitrary memory locations and achieve code execution.

MitigationDo not open untrusted .jb2 files in STDU Viewer. Await an official vendor patch for STDU Viewer that fixes the JB2 parsing vulnerability.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Stdu ViewerApplication
Affected:= 1.6.375

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify STDU Viewer is installed
    Check for STDU Viewer application on the system (look in Program Files, Program Files x86, or application directories)
    Affected if STDU Viewer is found on the system
  2. Identify installed version
    Right-click the STDU Viewer executable, select Properties, and check the Version tab for the product version
    Affected if Version is exactly 1.6.375
  3. Determine JB2 file handling capability
    Check if the application can open or has been used to open .jb2 image files, or verify JB2 support is present in the installation
    Affected if JB2 file parsing capability exists and the user processes JB2 files
  4. Check for recent JB2 file opening activity
    Review recent file open history, recent documents, or application file associations for .jb2 file type
    Affected if JB2 files have been opened with STDU Viewer

The environment is affected if STDU Viewer version 1.6.375 is installed and users open or process specially crafted JB2 image files with this application.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Do not open untrusted .jb2 files in STDU Viewer. Await an official vendor patch for STDU Viewer that fixes the JB2 parsing vulnerability.

Fix this in Stdu Viewer Scoped from the published advisory
  • Consultation6.0 h
  • Implementation16.0 h
  • Testing8.0 h
  • Review / QA4.0 h
34.0 hours of engineering $6,000
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $9,600.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2017-14300 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2017-14300 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data