Thermal Management Center FirmwareOperating system · Iceqube

CVE-2017-16714

CRITICAL · 9.8 CVSS v3.0 Published 2018-09-06
Fix available
A fix is available. Upgrade to 4.13 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
In Ice Qube Thermal Management Center versions prior to version 4.13, passwords are stored in plaintext in a file that is accessible without authentication.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Ice Qube Thermal Management Center versions prior to 4.13 store user passwords in plaintext within a file that can be accessed without any authentication, allowing unauthenticated attackers to retrieve valid credentials.

MitigationUpgrade to Ice Qube Thermal Management Center version 4.13 or later, which implements proper password hashing and removes the plaintext credential storage.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Thermal Management Center FirmwareOperating system
Affected:< 4.13

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify Ice Qube Thermal Management Center installation
    Locate the Ice Qube Thermal Management Center software or appliance in your environment. This is a thermal management system, often deployed as a standalone appliance or integrated software module.
    Affected if Ice Qube Thermal Management Center is present in the environment
  2. Check installed firmware version
    Access the system administrative interface or use the firmware version check command provided by the appliance to determine the current firmware version. Compare the version number to the affected range of versions prior to 4.13.
    Affected if The firmware version is below 4.13
  3. Locate the plaintext credential storage file
    Search for the file containing stored user credentials within the Ice Qube installation directory or web root. The vulnerability indicates this file stores passwords in plaintext and is accessible without authentication.
    Affected if A file containing plaintext user passwords exists and is accessible without authentication
  4. Verify unauthenticated access to credential file
    Attempt to access the credential storage file directly via HTTP request or file system access without providing login credentials. The vulnerability specifically states the file can be accessed without any authentication.
    Affected if The password file can be retrieved without any authentication credentials

The environment is affected if Ice Qube Thermal Management Center with firmware prior to version 4.13 is installed and a plaintext password file is accessible without authentication.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 4.13 or later
Fixed in 4.13
Interim mitigation

Upgrade to Ice Qube Thermal Management Center version 4.13 or later, which implements proper password hashing and removes the plaintext credential storage.

Recommended fix High confidence

Thermal Management Center firmware version 4.13 or later

  1. Obtain the Thermal Management Center firmware version 4.13 or later from the vendor (Ice Qube)
  2. Review vendor release notes for any special upgrade requirements or prerequisites
  3. Backup current configuration if supported by the system
  4. Upload and apply firmware version 4.13 or later following the vendor's standard firmware update procedure
  5. Verify the upgrade was successful and confirm the new version is running
  6. Change all passwords after upgrade as a security best practice since they may have been exposed

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Thermal Management Center Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2017-16714 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2017-16714 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data