Universal Multifunctional Electric Power Quality Meter FirmwareOperating system · Binom3

CVE-2017-5165

HIGH · 7.6 CVSS v3.0 Published 2017-02-13
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
83/100
Remediation priority · High
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The BINOM3 Electric Power Quality Meter web interface lacks anti-CSRF tokens, allowing attackers to craft malicious requests that execute silently when a logged-in user visits a malicious site. Since the device accepts requests without validating token authenticity, an attacker can trigger unauthorized configuration changes.

MitigationImplement per-session or per-request CSRF tokens for all sensitive functions (configuration changes, settings save). Validate tokens server-side before processing any state-changing request.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Universal Multifunctional Electric Power Quality Meter FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
High

CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Binom3 device is present on the network
    Access the web interface of the Binom3 Universal Multifunctional Electric Power Quality Meter by navigating to its IP address in a web browser. Verify the device model and firmware version are displayed in the interface header or system information page.
    Affected if The device is accessible and identifies as a Binom3 Electric Power Quality Meter with any firmware version.
  2. Locate configuration-related forms in the web interface
    Navigate to the settings or configuration sections of the web interface where users can modify device parameters (network settings, meter configuration, user management). Identify all HTML forms that perform state-changing operations.
    Affected if The web interface contains forms for making configuration changes.
  3. Inspect HTML source for anti-CSRF tokens
    Right-click on configuration forms and select 'View Page Source' or use browser developer tools to examine the HTML. Look for hidden input fields with names containing 'token', 'csrf', 'nonce', or similar security tokens within the form tags.
    Affected if No hidden anti-CSRF token fields are present in the HTML of configuration forms.
  4. Check form submission behavior
    Submit a configuration change through the web interface and observe the HTTP request using browser developer tools (Network tab). Examine whether the request includes any token parameters beyond standard form fields.
    Affected if The form submission HTTP POST request contains no token, nonce, or CSRF-specific parameter.
  5. Verify server-side token validation
    Compare the behavior when submitting the same configuration change with and without a fabricated token parameter. If the server accepts both requests without rejecting the invalid token, no server-side validation occurs.
    Affected if The server processes configuration requests regardless of token validity, indicating no server-side CSRF protection.

You are affected if you have a Binom3 Electric Power Quality Meter with its web interface accessible and the configuration forms lack anti-CSRF tokens in their HTML.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement per-session or per-request CSRF tokens for all sensitive functions (configuration changes, settings save). Validate tokens server-side before processing any state-changing request.

Fix this in Universal Multifunctional Electric Power Quality Meter Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA3.0 h
21.0 hours of engineering $3,680
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,888.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2017-5165 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2017-5165 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data