CVE-2017-8133
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedHuawei iManager NetEco with software V600R008C00 and V600R008C10 has a command injection vulnerability. An authenticated, remote attacker could exploit this vulnerability to send malicious packets to a target device. Successful exploit could enable a low privileged user to execute commands that a high privileged user could execute, causing the files to be tampered with or deleted.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceHuawei iManager NetEco versions V600R008C00 and V600R008C10 contain a command injection vulnerability allowing authenticated remote attackers to send malicious packets. Successful exploitation enables a low-privileged user to execute commands with high-privileged access, resulting in potential file tampering or deletion.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= v600r008c00= v600r008c10CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Verify NetEco product and versionLocate the iManager NetEco installation and check the version information, typically found in the product about page, installation directory, or system information panel. Confirm the exact version is V600R008C00 or V600R008C10.Affected if The installed version is exactly V600R008C00 or V600R008C10
-
Confirm management interface accessibilityDetermine if the NetEco web management interface (typically on port 8080 or 8443) is exposed to network accessible systems. Check firewall rules, NAT configurations, or reverse proxy settings that expose this interface.Affected if The management interface is reachable from untrusted or external networks
-
Review user account privilegesExamine the user accounts configured in NetEco to identify any low-privileged accounts that should not have elevated access. Check user role assignments and permission configurations.Affected if Low-privileged user accounts exist in the system and can access the management interface
-
Inspect system logs for suspicious commandsReview NetEco system logs, audit logs, and operating system command logs for unexpected or unauthorized command executions, especially those involving file operations or system modifications.Affected if Logs contain command executions that were not initiated by known administrators or that involve file tampering or deletion
You are affected if Huawei iManager NetEco version V600R008C00 or V600R008C10 is installed and its management interface is network-accessible to authenticated users.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply the vendor-supplied patch for this vulnerability. Until patched, restrict network access to the iManager NetEco management interface to trusted users only and monitor for suspicious command execution.
- Consultation6.0 h
- Implementation8.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,296.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2017-8133 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2017-8133 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data