Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedDell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 contain an improper error handling vulnerability. An unauthenticated attacker with physical access to the system could potentially exploit this vulnerability to get access to the u-boot shell.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceThis is an improper error handling vulnerability in Dell EMC iDRAC7 and iDRAC8 firmware versions prior to 2.61.60.60. An unauthenticated attacker with physical access to the server can exploit improper error handling to gain access to the u-boot shell, a bootloader environment that provides low-level system access.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 2.61.60.60< 2.61.60.60CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Physical
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify iDRAC modelAccess the iDRAC web interface, use racadm command 'racadm get iDRAC.Info', or check during server boot to confirm whether the device is iDRAC7 or iDRAC8Affected if The device is not iDRAC7 or iDRAC8 (other models are not affected by this CVE)
-
Check iDRAC firmware versionVia iDRAC web interface in the Overview > iDRAC Settings > Firmware page, or run 'racadm getversion' command line, or view during POST boot screenAffected if The firmware version is less than 2.61.60.60 (versions prior to this are affected)
-
Verify physical access exposureAssess whether unauthorized individuals can physically access the server housing the iDRACAffected if Physical access is possible for unauthenticated attackers - this is required for exploitation
You are affected if you have an iDRAC7 or iDRAC8 with firmware version below 2.61.60.60 AND physical access to the server is not restricted
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor data2.61.60.60
Update iDRAC firmware to version 2.61.60.60 or later. As a defense-in-depth measure, restrict physical access to servers hosting vulnerable iDRAC devices.
- Consultation3.0 h
- Implementation2.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,304.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2018-15776 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2018-15776 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data