Control For Beaglebone SlApplication · Codesys

CVE-2018-20026

HIGH · 7.5 CVSS v3.1 Published 2019-02-19
Fix available
A fix is available. Upgrade to 3.5.14.0 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Improper Communication Address Filtering in CODESYS V3 products prior to V3.5.14.0 allows potential unauthorized network communication access to the industrial control software, likely enabling remote attackers to send commands or access the runtime environment without proper validation of communication source addresses.

MitigationUpgrade CODESYS V3 products to version V3.5.14.0 or later to obtain the address filtering fix. For additional defense-in-depth, implement network segmentation to isolate industrial control system devices and restrict communication to authorized IP addresses/subnets.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Control For Beaglebone SlApplication
Affected:>= 3.0, < 3.5.14.0
Control For Empc A\/imx6 SlApplication
Affected:>= 3.0, < 3.5.14.0
Control For Iot2000 SlApplication
Affected:>= 3.0, < 3.5.14.0
Control For Linux SlApplication
Affected:>= 3.0, < 3.5.14.0
Control For Pfc100 SlApplication
Affected:>= 3.0, < 3.5.14.0
Control For Pfc200 SlApplication
Affected:>= 3.0, < 3.5.14.0
Control For Raspberry Pi SlApplication
Affected:>= 3.0, < 3.5.14.0
Control Rte SlApplication
Affected:>= 3.0, < 3.5.14.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed CODESYS product
    Locate the CODESYS Control runtime package on the system. Check the product name which will be one of: Codesys Control For Beaglebone, Codesys Control For Empc A/imx6, Codesys Control For Iot2000, Codesys Control For Linux, Codesys Control For Pfc100, Codesys Control For Pfc200, Codesys Control For Raspberry Pi, or Codesys Control Rte. This is typically visible in the CODESYS Development System or in the installed package information on the runtime device.
    Affected if The installed product matches any of the eight affected product names listed in the CVE.
  2. Check installed CODESYS version
    Open CODESYS Development System and navigate to the device or check the runtime package version. On Linux-based devices, you may find version information in the package manager or by checking the installed CODESYS Control package directly. Compare the version number against the affected range: >= 3.0 and < 3.5.14.0.
    Affected if The installed version is 3.0 or higher but lower than 3.5.14.0.
  3. Verify network communication is enabled
    Check if the CODESYS runtime has network communication ports (typically TCP ports 11740, 11741, or similar) open and listening. This can be done using netstat or ss commands: 'netstat -an | grep -E "11740|11741"' or by reviewing the runtime configuration for enabled communication interfaces.
    Affected if Network communication is enabled and the runtime is listening on network ports, exposing the address filtering vulnerability.
  4. Check address filtering configuration
    Examine the CODESYS runtime network configuration settings for any address filtering or access control lists. Look for settings related to AllowedClients, IPFilter, or similar address validation features. In the CODESYS Development System, check the device configuration under Network Adaptation or Communication Settings.
    Affected if Address filtering is disabled, not configured, or allows unrestricted access (0.0.0.0/0 or similar), indicating the vulnerability is present.

The environment is affected if a CODESYS Control product from the affected list is installed with a version between 3.0 and 3.5.14.0 and has network communication enabled, as the improper address filtering allows unauthorized remote access.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 3.5.14.0 or later
Fixed in 3.5.14.0
Interim mitigation

Upgrade CODESYS V3 products to version V3.5.14.0 or later to obtain the address filtering fix. For additional defense-in-depth, implement network segmentation to isolate industrial control system devices and restrict communication to authorized IP addresses/subnets.

Fix this in Control For Beaglebone Sl Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA2.0 h
20.0 hours of engineering $3,500
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-20026 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-20026 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data