Oncell G3150 Hspa T FirmwareOperating system · Moxa

CVE-2018-5449

MEDIUM · 6.5 CVSS v3.0 Published 2018-03-05
Fix available
A fix is available. Upgrade to after 1.4 or later.
See remediation →
70/100
Remediation priority · Elevated
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A NULL pointer dereference vulnerability exists in Moxa OnCell G3100-HSPA Series cellular gateway firmware versions 1.4 Build 16062919 and prior. The application fails to validate pointers before dereferencing them, allowing an attacker to trigger a NULL pointer that causes the device to crash or become unresponsive, resulting in denial of service.

MitigationApply the vendor-supplied firmware patch to address the NULL pointer dereference. If no patch is available, implement network segmentation and access controls to limit exposure to untrusted attackers, and monitor for device availability issues.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Oncell G3150 Hspa T FirmwareOperating system
Affected:<= 1.4
Oncell G3110 Hspa T FirmwareOperating system
Affected:<= 1.4
Oncell G3150 Hspa FirmwareOperating system
Affected:<= 1.4
Oncell G3110 Hspa FirmwareOperating system
Affected:<= 1.4

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Access the device web interface or console and check the model name. Look for OnCell G3110-HSPA, G3110-HSPA-T, G3150-HSPA, or G3150-HSPA-T markings on the device or in the management interface.
    Affected if The device is NOT one of these four models (G3110-HSPA, G3110-HSPA-T, G3150-HSPA, G3150-HSPA-T)
  2. Check the installed firmware version
    In the device web interface, navigate to System Settings > Firmware Update or System Information to view the current firmware version. Alternatively, use the serial console or SNMP to query the firmware version.
    Affected if The firmware version is 1.4 or lower, or specifically shows Build 16062919 or earlier
  3. Verify network exposure
    Check the device network configuration to determine if it is directly accessible from untrusted networks (such as the internet or DMZ). Review firewall rules, NAT configurations, and access control lists surrounding the device.
    Affected if The device is exposed to untrusted network segments without proper network segmentation or access controls

You are affected if you have a Moxa OnCell G3110 or G3150 device with firmware version 1.4 or lower that is accessible to untrusted attackers who can trigger the NULL pointer dereference.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 1.4
Interim mitigation

Apply the vendor-supplied firmware patch to address the NULL pointer dereference. If no patch is available, implement network segmentation and access controls to limit exposure to untrusted attackers, and monitor for device availability issues.

Fix this in Oncell G3150 Hspa T Firmware Scoped from the published advisory
  • Consultation3.0 h
  • Implementation4.0 h
  • Testing3.0 h
  • Review / QA2.0 h
12.0 hours of engineering $2,130
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,408.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-5449 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-5449 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data