3par Service ProviderOperating system · Hp

CVE-2018-7096

CRITICAL · 9.8 CVSS v3.0 Published 2018-08-14
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-4.4.0.GA-110(MU7). The vulnerability may be exploited remotely to allow code execution.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A remote code execution vulnerability exists in HPE 3PAR Service Processor (SP) versions prior to SP-4.4.0.GA-110(MU7). The Service Processor is a dedicated management appliance for 3PAR storage arrays that handles firmware updates and support functions. The vulnerability allows unauthenticated remote attackers to execute arbitrary code on the SP system.

MitigationUpgrade the 3PAR Service Processor to version SP-4.4.0.GA-110(MU7) or later to remediate this vulnerability. As this is a critical infrastructure component, plan the upgrade during a maintenance window and verify storage array functionality post-upgrade.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
3par Service ProviderOperating system
Affected:= sp-4.2.0= sp-4.3.0= sp-4.4.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify HPE 3PAR Service Processor in your environment
    Locate the Service Processor appliance that manages your 3PAR storage array. This is a dedicated management appliance separate from the storage array itself.
    Affected if The system is an HPE 3PAR Service Processor appliance
  2. Determine the installed Service Processor version
    Access the SP management interface or use the SP command-line interface to retrieve the current firmware version. Look for version information in the system diagnostics or support logs.
    Affected if The installed version is sp-4.2.0, sp-4.3.0, or sp-4.4.0 (any version prior to SP-4.4.0.GA-110(MU7))
  3. Verify version against the fixed release
    Compare your installed SP version number to SP-4.4.0.GA-110(MU7). Versions numerically lower than 4.4.0 GA-110 or that do not include the MU7 designation are in the affected range.
    Affected if The version is earlier than SP-4.4.0.GA-110(MU7) or the version cannot be confirmed as MU7 or later

You are affected if your HPE 3PAR Service Processor is running any version earlier than SP-4.4.0.GA-110(MU7), specifically versions sp-4.2.0, sp-4.3.0, or sp-4.4.0.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Upgrade the 3PAR Service Processor to version SP-4.4.0.GA-110(MU7) or later to remediate this vulnerability. As this is a critical infrastructure component, plan the upgrade during a maintenance window and verify storage array functionality post-upgrade.

Recommended fix Moderate confidence

SP-4.4.0.GA-110(MU7)

  1. Locate and download SP-4.4.0.GA-110(MU7) or later from the HPE support portal (support.hpe.com)
  2. Review the HPE 3PAR Service Processor release notes for SP-4.4.0.GA-110(MU7) for specific installation instructions
  3. Back up the current Service Processor configuration before proceeding
  4. Apply the upgrade following HPE's documented Service Processor update procedure
  5. Verify the upgrade was successful by checking the SP version post-installation

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in 3par Service Provider Scoped from the published advisory
  • Consultation4.0 h
  • Implementation4.0 h
  • Testing4.0 h
  • Review / QA2.0 h
14.0 hours of engineering $2,480
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,968.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-7096 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-7096 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data