Powersuite 2Application · Schneider Electric

CVE-2018-7796

MEDIUM · 6.3 CVSS v3.0 Published 2018-12-24
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
70/100
Remediation priority · Elevated
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A buffer overflow vulnerability exists in PowerSuite 2 (VW3A8104 and all patch versions) where improper bounds checking before a memcpy call allows data to exceed allocated buffer boundaries, leading to memory corruption and potential program instability.

MitigationApply any available vendor patches for PowerSuite 2; if no patch exists, implement input validation and size checking before memcpy operations to ensure source data does not exceed destination buffer capacity.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Powersuite 2Application
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm PowerSuite 2 installation
    Locate the PowerSuite 2 application on the system. Check for the executable VW3A8104 or the PowerSuite 2 program folder in typical installation directories (e.g., C:\Program Files\Schneider Electric\PowerSuite 2 or C:\Schneider Electric\PowerSuite 2).
    Affected if PowerSuite 2 (VW3A8104) is found installed on the system.
  2. Identify installed version
    Right-click the PowerSuite 2 executable, select Properties, then view the Details tab for version information. Alternatively, open PowerSuite 2 and navigate to Help > About to display the exact version and build number.
    Affected if The installed version cannot be determined or is any version of PowerSuite 2.
  3. Verify version against affected range
    Compare the identified version number to the affected product designation (VW3A8104 and all patch versions). Schneider Electric lists this as all versions of PowerSuite 2.
    Affected if The version is VW3A8104 or any subsequent patch version of PowerSuite 2.
  4. Confirm vulnerable functionality is in use
    This buffer overflow occurs during memcpy operations within the application. The vulnerability is inherent to the software when processing data. No specific feature toggle is required; the flaw exists in the core application code when handling data that triggers the unbounded memcpy.
    Affected if PowerSuite 2 is installed and operational, meaning the vulnerable code path is present.

If PowerSuite 2 (VW3A8104) is installed at any version, the environment is affected by this vulnerability.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply any available vendor patches for PowerSuite 2; if no patch exists, implement input validation and size checking before memcpy operations to ensure source data does not exceed destination buffer capacity.

Fix this in Powersuite 2 Scoped from the published advisory
  • Consultation8.0 h
  • Implementation12.0 h
  • Testing16.0 h
  • Review / QA8.0 h
44.0 hours of engineering $7,600
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $12,160.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-7796 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-7796 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data