Lenovoemc FirmwareOperating system · Lenovo

CVE-2018-9076

HIGH · 8.1 CVSS v3.0 Published 2018-09-28
Fix available
A fix is available. Upgrade to after 4.1.402.34662 or later.
See remediation →
90/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when changing the name of a share, an attacker can craft a command injection payload using backtick "``" characters in the name parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This is a command injection vulnerability in Iomega, Lenovo, and LenovoEMC NAS devices where the share name parameter fails to sanitize backtick characters (`) during share name modification. An attacker can inject shell commands via command substitution using backticks, achieving arbitrary code execution as the root user. The attack requires the __c and iomega parameters, suggesting it's exploitable through the web interface.

MitigationUpgrade NAS firmware to a version later than 4.1.402.34662; if no patch is available, implement strict input validation to reject special characters including backticks in share name parameters at the application layer.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Lenovoemc FirmwareOperating system
Affected:<= 4.1.402.34662

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if the device is a LenovoEMC or Iomega NAS
    Access the device's web interface or check the device model/serial number. Look for 'LenovoEMC', 'Iomega', or 'Lenovo' branding in the NAS management console or physical device label.
    Affected if The device is a LenovoEMC or Iomega NAS product.
  2. Check the installed firmware version
    Log into the NAS administrative interface and navigate to System Settings or About section. Look for the firmware version number (e.g., 4.1.402.34662 or similar).
    Affected if The firmware version is 4.1.402.34662 or earlier.
  3. Verify if the legacy web management interface is accessible
    Attempt to access the web interface via HTTP/HTTPS on the typical NAS management ports (usually 80, 443, 8080, or 8443). Look for endpoints containing '__c' and 'iomega' parameters in URLs or form submissions.
    Affected if The legacy Iomega/EMC web interface is accessible and accepts share name modifications.
  4. Check if remote administration is enabled
    In the NAS settings, look for remote access or remote administration settings. Determine if the management interface is exposed to untrusted networks.
    Affected if Remote administration is enabled and the NAS is accessible from untrusted networks.
  5. Review share names for unexpected characters
    In the NAS storage/shares management panel, inspect all configured share names. Look for any shares containing backtick characters (`) or other shell metacharacters that were not intentionally created.
    Affected if Any share name contains backtick characters or appears to have been modified unexpectedly.

A user is affected if they have a LenovoEMC or Iomega NAS running firmware version 4.1.402.34662 or earlier, with the legacy web management interface accessible and potentially exposed to network attackers.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 4.1.402.34662
Interim mitigation

Upgrade NAS firmware to a version later than 4.1.402.34662; if no patch is available, implement strict input validation to reject special characters including backticks in share name parameters at the application layer.

Fix this in Lenovoemc Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA3.0 h
21.0 hours of engineering $3,680
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,888.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2018-9076 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2018-9076 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data