Electric Fr Configurator2 FirmwareOperating system · Mitsubishielectric

CVE-2019-10976

MEDIUM · 5.5 CVSS v3.0 Published 2019-07-26
Fix available
A fix is available. Upgrade to 1.16s or later.
See remediation →
58/100
Remediation priority · Elevated
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This is an XML External Entity (XXE) injection vulnerability in Mitsubishi Electric FR Configurator2. The application fails to sanitize XML input when parsing project and template files (.frc2), allowing attackers to inject malicious XML with external entity references to read arbitrary files from the system.

MitigationDo not open untrusted .frc2 files from unknown sources. Apply vendor patches when released and implement file type validation/monitoring at the network perimeter.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Electric Fr Configurator2 FirmwareOperating system
Affected:< 1.16s

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify FR Configurator2 installation
    Check for the presence of Mitsubishi Electric FR Configurator2 in the system (typically under Program Files or Program Files (x86)). On Windows, check registry keys under HKLM\SOFTWARE\Mitsubishi Electric or look for the executable file (FR Configurator2.exe).
    Affected if The software is installed on the system.
  2. Determine installed version number
    Right-click the FR Configurator2.exe file, select Properties, then view the Details tab to find the File Version. Alternatively, open the application and navigate to Help > Version Information.
    Affected if The version number is lower than 1.16s.
  3. Confirm .frc2 file handling capability
    FR Configurator2 is designed to open project and template files with the .frc2 extension. This is the application's primary function and cannot be disabled.
    Affected if The application is capable of opening .frc2 files (this is true for any installation).
  4. Inspect network traffic or logs for XXE indicators
    Monitor network connections and application logs for unusual outbound requests or file access patterns that could indicate exploitation attempts via malicious .frc2 files.
    Affected if Suspicious network requests to internal resources or file system access from the application process are observed.

A user is affected if Mitsubishi Electric FR Configurator2 version 1.16s or lower is installed and the application is used to open .frc2 project or template files.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 1.16s or later
Fixed in 1.16s
Interim mitigation

Do not open untrusted .frc2 files from unknown sources. Apply vendor patches when released and implement file type validation/monitoring at the network perimeter.

Fix this in Electric Fr Configurator2 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing2.0 h
  • Review / QA1.0 h
9.0 hours of engineering $1,600
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,560.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-10976 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-10976 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data