Integrated Lights Out 5 FirmwareOperating system · Hp

CVE-2019-11983

HIGH · 7.0 CVSS v3.0 Published 2019-06-05
Fix available
A fix is available. Upgrade to after 2.61b or later.
See remediation →
79/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A remote buffer overflow vulnerability exists in HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61b for Gen9 servers and iLO 5 prior to v1.39 for Gen10 servers. The vulnerability allows remote attackers to potentially execute arbitrary code or cause a denial of service due to insufficient bounds checking in the iLO firmware's remote management interface.

MitigationUpgrade HPE iLO firmware to version v2.61b or later for iLO 4 (Gen9) and v1.39 or later for iLO 5 (Gen10). Apply during a scheduled maintenance window following HPE's firmware update procedures.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Integrated Lights Out 5 FirmwareOperating system
Affected:<= 1.39
Integrated Lights Out 4 FirmwareOperating system
Affected:<= 2.61b

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
High

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm HPE iLO management interface is present
    Access the iLO web interface by browsing to the server's iLO IP address, or use the HPONCFG command-line utility (hponcfg -g) to query the iLO subsystem
    Affected if The system does not have an iLO management interface, this CVE does not apply
  2. Identify iLO generation (iLO 4 vs iLO 5)
    In the iLO web interface, go to Information > Overview. iLO 4 appears on Gen9 servers, iLO 5 on Gen10 servers. Alternatively, check the firmware version number format: iLO 4 versions typically start with 2.x, iLO 5 versions with 1.x
    Affected if Unable to determine iLO generation, version comparison may be invalid
  3. Check installed iLO firmware version
    In the iLO web interface, navigate to Administration > Firmware. Note the firmware version displayed. Alternatively, run 'hponcfg -g' from the server OS to retrieve the iLO firmware version
    Affected if The installed version cannot be determined or is not displayed
  4. Compare version against affected ranges
    For iLO 4: if version is less than 2.61b, the system is affected. For iLO 5: if version is less than 1.39, the system is affected. Note that versions 2.61b and 1.39 and later are patched
    Affected if iLO 4 version <= 2.61b OR iLO 5 version <= 1.39

A system is affected if it runs HPE iLO 4 firmware version 2.61b or lower, or iLO 5 firmware version 1.39 or lower, on Gen9 or Gen10 servers respectively.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 2.61b
Interim mitigation

Upgrade HPE iLO firmware to version v2.61b or later for iLO 4 (Gen9) and v1.39 or later for iLO 5 (Gen10). Apply during a scheduled maintenance window following HPE's firmware update procedures.

Fix this in Integrated Lights Out 5 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation2.0 h
  • Testing2.0 h
  • Review / QA1.0 h
7.0 hours of engineering $1,240
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,984.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-11983 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-11983 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data