Kace Systems Management ApplianceApplication · Quest

CVE-2019-13077

MEDIUM · 6.1 CVSS v3.1 Published 2019-11-06
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
68/100
Remediation priority · Elevated
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Quest KACE Systems Management Appliance Server Center 9.1.317 has an XSS vulnerability (via the sam_detail_titled.php SAM_TYPE parameter) that allows an attacker to create a malicious link in order to attack authenticated users.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Quest KACE Systems Management Appliance Server Center 9.1.317 contains a reflected cross-site scripting (XSS) vulnerability in the sam_detail_titled.php file via the SAM_TYPE parameter. An authenticated attacker can craft malicious URLs containing JavaScript payloads that execute in the browsers of authenticated users who click the link.

MitigationImplement input validation and output encoding for the SAM_TYPE parameter in sam_detail_titled.php to prevent injection of malicious script content.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Kace Systems Management ApplianceApplication
Affected:= 9.1.317

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify KACE SMA version
    Log into the KACE Systems Management Appliance admin interface and navigate to the System Overview or About section to confirm the installed version is 9.1.317. Alternatively, check the version via the appliance's system information page or release notes.
    Affected if The installed version is exactly 9.1.317 (the specific affected version)

Your environment is affected only if the installed Quest KACE Systems Management Appliance version is exactly 9.1.317 and the sam_detail_titled.php file with the vulnerable SAM_TYPE parameter is accessible to authenticated users.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement input validation and output encoding for the SAM_TYPE parameter in sam_detail_titled.php to prevent injection of malicious script content.

Fix this in Kace Systems Management Appliance Scoped from the published advisory
  • Consultation2.0 h
  • Implementation3.0 h
  • Testing2.0 h
  • Review / QA1.0 h
8.0 hours of engineering $1,420
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,272.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-13077 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-13077 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data