Kace Systems Management ApplianceApplication · Quest

CVE-2019-13080

MEDIUM · 5.4 CVSS v3.1 Published 2019-11-06
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
58/100
Remediation priority · Elevated
Remotely reachable

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Quest KACE Systems Management Appliance Server Center 9.1.317 has an XSS vulnerability (via an SVG image and HTML file) that allows an authenticated user to execute arbitrary JavaScript in an administrator's browser.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Quest KACE Systems Management Appliance Server Center 9.1.317 contains a stored XSS vulnerability where an authenticated user can upload malicious SVG images or HTML files containing arbitrary JavaScript that executes in an administrator's browser when the file is viewed.

MitigationImplement strict input validation and sanitization for file uploads, specifically sanitizing SVG and HTML content to strip executable scripts, and apply output encoding when rendering uploaded files.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Kace Systems Management ApplianceApplication
Affected:= 9.1.317

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify KACE SMA version
    Access the Server Center admin interface and navigate to System Settings > General Settings, or check the login page footer for version 9.1.317
    Affected if Version displayed is exactly 9.1.317
  2. Confirm file upload capability exists
    Log into the KACE SMA admin panel and navigate to the file upload or asset attachment feature (often under Inventory, Assets, or Scripting sections)
    Affected if The file upload interface is accessible and accepts file attachments
  3. Check uploaded file rendering
    Upload a test file (such as an image or document) through the upload feature, then locate and view that file in the admin interface to confirm files are rendered/displayed
    Affected if Uploaded files are accessible and rendered within the admin panel for viewing by administrators

You are affected if the installed Quest KACE Systems Management Appliance version is exactly 9.1.317 and the file upload and viewing functionality is enabled and accessible in the Server Center.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement strict input validation and sanitization for file uploads, specifically sanitizing SVG and HTML content to strip executable scripts, and apply output encoding when rendering uploaded files.

Fix this in Kace Systems Management Appliance Scoped from the published advisory
  • Consultation2.0 h
  • Implementation6.0 h
  • Testing3.0 h
  • Review / QA2.0 h
13.0 hours of engineering $2,290
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,664.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-13080 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-13080 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data