Tasy EmrApplication · Philips

CVE-2019-13557

MEDIUM · 5.3 CVSS v3.1 Published 2019-11-08
Fix available
A fix is available. Upgrade to after 3.02.1757 or later.
See remediation →
62/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Tasy EMR and WebPortal versions 3.02.1757 and prior contain an information exposure vulnerability that allows remote unauthenticated attackers to access sensitive system and configuration information through the web portal interface.

MitigationUpgrade to a patched version of Tasy EMR/WebPortal beyond 3.02.1757 and ensure network access to the EMR system is restricted to authorized personnel and trusted networks.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Tasy EmrApplication
Affected:<= 3.02.1744
Tasy WebportalApplication
Affected:<= 3.02.1757

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed Tasy EMR version
    Access the EMR administration console or check system configuration files for the version number, typically found in the About or System Information section of the EMR application
    Affected if The displayed version is 3.02.1744 or lower
  2. Identify installed Tasy WebPortal version
    Access the WebPortal administration panel or check the WebPortal configuration files for the version number, typically accessible via the Help or System Info page
    Affected if The displayed version is 3.02.1757 or lower
  3. Verify web portal authentication status
    Attempt to access the Tasy WebPortal interface without providing credentials and observe if sensitive system or configuration information is returned
    Affected if The portal returns sensitive system or configuration data without requiring login credentials
  4. Check network exposure of the web portal
    Review firewall rules, network configurations, and access control lists to determine if the Tasy WebPortal is reachable from untrusted or external networks
    Affected if The web portal is accessible from networks other than trusted internal networks without proper access controls

A system is affected if it runs Tasy EMR version 3.02.1744 or lower, or Tasy WebPortal version 3.02.1757 or lower, AND the web portal interface is accessible to unauthenticated remote attackers.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 3.02.1757
Interim mitigation

Upgrade to a patched version of Tasy EMR/WebPortal beyond 3.02.1757 and ensure network access to the EMR system is restricted to authorized personnel and trusted networks.

Fix this in Tasy Emr Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-13557 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-13557 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data