Webaccess\/hmi DesignerApplication · Advantech

CVE-2019-16899

HIGH · 7.5 CVSS v3.1 Published 2019-09-26
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
In Advantech WebAccess/HMI Designer 2.1.9.31, Data from a Faulting Address controls Code Flow starting at PM_V3!CTagInfoThreadBase::GetNICInfo+0x0000000000512918.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A control flow hijack vulnerability exists in Advantech WebAccess/HMI Designer 2.1.9.31 where data from an attacker-controlled memory address (faulting address) influences code execution flow in the PM_V3!CTagInfoThreadBase::GetNICInfo function. This indicates a memory corruption issue allowing potential arbitrary code execution.

MitigationApply vendor-supplied patches when available. Until then, restrict network access to the HMI Designer system and implement network segmentation to limit exposure of this industrial control system component.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Webaccess\/hmi DesignerApplication
Affected:= 2.1.9.31

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Locate WebAccess/HMI Designer installation directory
    Check common installation paths such as C:\Program Files\Advantech\WebAccess\HMI Designer or C:\Advantech\WebAccess\HMI Designer. Use file explorer or command: dir /s /b "PM_V3.dll" 2>nul
    Affected if The product is not installed or the PM_V3.dll component is not found in expected directories
  2. Verify the installed version number
    Locate the version information for HMI Designer. Right-click the executable (typically HMIDesigner.exe in the installation folder), select Properties, and check the File Version or Product Version field. Alternatively, use PowerShell: Get-ItemProperty "C:\Program Files\Advantech\WebAccess\HMI Designer\HMIDesigner.exe" | Select-Object VersionInfo
    Affected if The Product Version or File Version shows exactly 2.1.9.31
  3. Confirm the vulnerable PM_V3.dll component version
    Navigate to the PM_V3.dll file in the installation folder (commonly in bin or runtime subdirectory), right-click and view Properties, or run: powershell (Get-Item "path\to\PM_V3.dll").VersionInfo
    Affected if PM_V3.dll version matches 2.1.9.31 or is listed as version 2.1.9.31 specifically
  4. Check if HMI Designer service or runtime is actively running
    Open Task Manager or use command: tasklist | findstr -i "HMI Designer" or check services.msc for WebAccess/HMI Designer related services
    Affected if The HMI Designer application or its runtime components are currently executing on the system

The system is affected if Advantech WebAccess/HMI Designer version 2.1.9.31 is installed, particularly if the PM_V3.dll component at version 2.1.9.31 is present and the application is in use.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor-supplied patches when available. Until then, restrict network access to the HMI Designer system and implement network segmentation to limit exposure of this industrial control system component.

Fix this in Webaccess\/hmi Designer Scoped from the published advisory
  • Consultation6.0 h
  • Implementation12.0 h
  • Testing6.0 h
  • Review / QA3.0 h
27.0 hours of engineering $4,800
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,680.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-16899 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-16899 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data