Pb610 Panel Builder 600Application · Abb

CVE-2019-18996

HIGH · 7.8 CVSS v3.1 Published 2019-12-18
Fix available
A fix is available. Upgrade to after 2.8.0.424 or later.
See remediation →
81/100
Remediation priority · High
No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

The HMIStudio component in ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier has insecure DLL loading due to path settings that accept DLLs from outside the program directory. An attacker with local file system access can place a malicious DLL in a location from which the application will load it, resulting in arbitrary code execution in the application's context.

MitigationUpgrade to a patched version of ABB PB610 Panel Builder 600. Additionally, restrict file system access to prevent unauthorized users from placing DLLs in locations from which the application loads libraries.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Pb610 Panel Builder 600Application
Affected:<= 2.8.0.424

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Verify ABB PB610 Panel Builder 600 installation
    Open Windows Control Panel > Programs and Features, or check the installation directory for HMIStudio or Panel Builder 600 executables
    Affected if The software is installed on the system
  2. Determine installed version
    Right-click the main Panel Builder executable (typically PanelBuilder600.exe or similar), select Properties, and check the File Version field in the Details tab
    Affected if The reported version is 2.8.0.424 or earlier
  3. Locate HMIStudio component
    Search for HMIStudio.exe or related DLLs in the installation directory and common application data folders
    Affected if HMIStudio executable or its DLLs are present on the system
  4. Check for unauthorized DLL placement opportunities
    Review folder permissions on directories from which the application may load DLLs, including the application directory, system paths, and user-writable locations
    Affected if Non-privileged users can write to directories in the application's DLL search path (other than the program directory)
  5. Verify DLL loading behavior
    Use Process Monitor or similar tool to observe DLL load attempts when launching HMIStudio, checking for loads from paths outside the program directory
    Affected if The application loads DLLs from directories outside its installed folder

A user is affected if ABB PB610 Panel Builder 600 version 2.8.0.424 or earlier is installed and the HMIStudio component can load DLLs from locations outside the program directory.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 2.8.0.424
Interim mitigation

Upgrade to a patched version of ABB PB610 Panel Builder 600. Additionally, restrict file system access to prevent unauthorized users from placing DLLs in locations from which the application loads libraries.

Fix this in Pb610 Panel Builder 600 Scoped from the published advisory
  • Consultation8.0 h
  • Implementation16.0 h
  • Testing12.0 h
  • Review / QA8.0 h
44.0 hours of engineering $7,720
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $12,352.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-18996 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-18996 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data