Cs31x FirmwareOperating system · Lexmark

CVE-2019-19773

MEDIUM · 5.4 CVSS v3.1 Published 2020-03-06
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
58/100
Remediation priority · Elevated
Remotely reachable

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Various Lexmark products have stored XSS in the embedded web server used in older generation Lexmark devices. Affected products are available in http://support.lexmark.com/index?page=content&id=TE935&locale=en&userlocale=EN_US.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Stored Cross-Site Scripting (XSS) vulnerability in the embedded web server of older generation Lexmark devices. The malicious script is persisted on the device and executes when users access affected pages, potentially allowing session hijacking or credential theft.

MitigationApply available firmware updates from Lexmark's support portal (refer to TE935). If updates are unavailable, consider network isolating affected devices or disabling the web management interface.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Cs31x FirmwareOperating system
Affected:<= lw74.vyl.p267
Cs41x FirmwareOperating system
Affected:<= lw74.vy2.p267
Cs51x FirmwareOperating system
Affected:<= lw74.vy4.p267
Cx310 FirmwareOperating system
Affected:<= lw74.gm2.p267
Cx410 FirmwareOperating system
Affected:<= lw74.gm4.p267
Xc2130 FirmwareOperating system
Affected:<= lw74.gm4.p267
Cx510 FirmwareOperating system
Affected:<= lw74.gm7.p267
Xc2132 FirmwareOperating system
Affected:<= lw74.gm7.p267

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
Low
User interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the Lexmark device model
    Access the device's web interface or print a configuration page to confirm the exact model number (Cs31x, Cs41x, Cs51x, Cx310, Cx410, Xc2130, Cx510, or Xc2132)
    Affected if The device model is NOT one of these eight models - the vulnerability does not apply
  2. Check the installed firmware version
    In the web interface, navigate to Settings > General Setup > About, or print a configuration page to locate the firmware version string
    Affected if The firmware version is at or below lw74.vyl.p267 (Cs31x), lw74.vy2.p267 (Cs41x), lw74.vy4.p267 (Cs51x/Cx410/Xc2130), lw74.gm2.p267 (Cx310), or lw74.gm7.p267 (Cx510/Xc2132)
  3. Confirm the embedded web server is enabled
    In the web interface, verify that HTTP/HTTPS management access is available under Settings > General Setup > Network/Ports, or check if TCP port 80 or 443 is responding
    Affected if The web server is disabled and not accessible - the attack surface is not present; however, if it is enabled, the stored XSS could trigger for users accessing the interface

Your device is affected if it is a Lexmark Cs31x, Cs41x, Cs51x, Cx310, Cx410, Xc2130, Cx510, or Xc2132 with firmware at or below the version thresholds AND the embedded web management interface is enabled.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply available firmware updates from Lexmark's support portal (refer to TE935). If updates are unavailable, consider network isolating affected devices or disabling the web management interface.

Fix this in Cs31x Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-19773 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-19773 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm