Modicon M100 FirmwareOperating system · Schneider Electric

CVE-2019-6820

HIGH · 8.2 CVSS v3.1 Published 2019-05-22
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
91/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This vulnerability allows unauthenticated modification of network configuration (IP address, subnet mask, gateway) on affected Schneider Electric Modicon and PacDrive controllers via specially crafted Ethernet frames. The lack of authentication for this critical network configuration function enables an attacker to disrupt device communication or potentially redirect network traffic by changing the IP settings without any credentials.

MitigationImplement network segmentation and firewall rules to restrict unauthorized Ethernet traffic to industrial control devices. Apply vendor-supplied firmware patches when available and monitor network traffic for anomalous configuration change requests.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Modicon M100 FirmwareOperating system
Affected:all versions
Modicon M200 FirmwareOperating system
Affected:all versions
Modicon M221 FirmwareOperating system
Affected:all versions
Atv Imc Drive Controller FirmwareOperating system
Affected:all versions
Modicon M241 FirmwareOperating system
Affected:all versions
Modicon M251 FirmwareOperating system
Affected:all versions
Modicon M258 FirmwareOperating system
Affected:all versions
Modicon Lmc058 FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
Low
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify affected Schneider Electric controllers in your environment
    Inventory your industrial control devices and verify if any of the following models are present: Modicon M100, M200, M221, M241, M251, M258, LMC058, or ATV IMC Drive Controller. Check device nameplates, asset inventories, or network scans for these model numbers.
    Affected if Any of these specific Schneider Electric controller models are present on the network
  2. Verify network management interface exposure
    Determine if the affected controllers have their Ethernet management interfaces enabled and accessible on the network segment where untrusted devices could send Ethernet frames. Check network diagrams and access control lists.
    Affected if The controller Ethernet interfaces are reachable from network segments with untrusted or unauthorized devices
  3. Check for unauthenticated network configuration capability
    Examine whether the device network configuration functions (IP address, subnet mask, gateway settings) can be modified through Ethernet-based protocols without requiring authentication credentials.
    Affected if Network configuration parameters can be changed via Ethernet frames without authentication
  4. Monitor for configuration change network traffic
    Use a network sniffer or IDS to capture and inspect Ethernet traffic destined for the controller IP address on ports typically used for network management. Look for anomalous or unexpected configuration change packets.
    Affected if Unauthenticated or unexpected network configuration packets are observed targeting the controller

You are affected if any of the listed Schneider Electric Modicon or ATV IMC controllers are present on a network where untrusted Ethernet frames can reach the device's management interface without authentication controls preventing unauthorized network configuration changes.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Implement network segmentation and firewall rules to restrict unauthorized Ethernet traffic to industrial control devices. Apply vendor-supplied firmware patches when available and monitor network traffic for anomalous configuration change requests.

Fix this in Modicon M100 Firmware Scoped from the published advisory
  • Consultation8.0 h
  • Implementation16.0 h
  • Testing12.0 h
  • Review / QA6.0 h
42.0 hours of engineering $7,360
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $11,776.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-6820 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-6820 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data