Wiser For Knx FirmwareOperating system · Schneider Electric

CVE-2019-6832

HIGH · 8.3 CVSS v3.1 Published 2019-09-17
Fix available
A fix is available. Upgrade to 2.4.0 or later.
See remediation →
90/100
Remediation priority · Urgent
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Authentication bypass vulnerability (CWE-287) in spaceLYnk and Wiser for KNX building automation controllers allows unauthenticated attackers to bypass authentication mechanisms and gain control of the system. The vulnerability affects all versions prior to 2.4.0.

MitigationUpgrade spaceLYnk and Wiser for KNX to version 2.4.0 or later to incorporate the authentication fix. If immediate upgrade is not possible, restrict network access to these devices and monitor for unauthorized access attempts.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Wiser For Knx FirmwareOperating system
Affected:< 2.4.0
Spacelynk FirmwareOperating system
Affected:< 2.4.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
Low

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify installed building automation controllers
    Locate Schneider Electric spaceLYnk or Wiser for KNX devices on your network or in your physical inventory. Check network scans, device inventories, or physical asset lists for these specific product names.
    Affected if Either product is present in the environment
  2. Determine the firmware version
    Access the device's web management interface or use the device's built-in version check feature (typically found in System > Information or About sections) to retrieve the currently installed firmware version.
    Affected if The firmware version cannot be determined or is unknown
  3. Compare version against vulnerable range
    Compare the identified firmware version number to the affected range: any version prior to 2.4.0 (for example, 2.3.x, 2.2.x, 2.1.x, 2.0.x, 1.x). Note that version 2.4.0 and later are NOT affected.
    Affected if The installed version is less than 2.4.0 (for example, 2.3.1, 2.2.0, or 1.9.5)
  4. Verify network accessibility of management interface
    Determine if the device's web management interface (typically HTTP/HTTPS on ports 80 or 443) is accessible from untrusted networks, the internet, or network segments outside the building automation network.
    Affected if The management interface is exposed to untrusted networks and the firmware version is below 2.4.0

You are affected if Schneider Electric spaceLYnk or Wiser for KNX with firmware version prior to 2.4.0 is present and its management interface is network-accessible.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 2.4.0 or later
Fixed in 2.4.0
Interim mitigation

Upgrade spaceLYnk and Wiser for KNX to version 2.4.0 or later to incorporate the authentication fix. If immediate upgrade is not possible, restrict network access to these devices and monitor for unauthorized access attempts.

Fix this in Wiser For Knx Firmware Scoped from the published advisory
  • Consultation8.0 h
  • Implementation4.0 h
  • Testing8.0 h
  • Review / QA4.0 h
24.0 hours of engineering $4,240
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,784.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2019-6832 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2019-6832 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data