Mir100 FirmwareOperating system · Mobile Industrial Robots

CVE-2020-10276

CRITICAL · 9.8 CVSS v3.1 Published 2020-06-24
Fix available
A fix is available. Upgrade to after 2.8.1.1 or later.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A safety PLC contains a default password that is documented in user manuals and is easily discoverable. An attacker with knowledge of this default password can upload a manipulated program to the safety PLC that disables the emergency stop function, creating a critical safety hazard. The laser scanner configuration may also be altered, further compromising device safety.

MitigationImmediately change the default password to a strong, unique password following industrial control system security best practices, and implement proper access control mechanisms to prevent unauthorized changes to safety-critical systems.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Mir100 FirmwareOperating system
Affected:<= 2.8.1.1
Mir200 FirmwareOperating system
Affected:all versions
Mir250 FirmwareOperating system
Affected:all versions
Mir500 FirmwareOperating system
Affected:all versions
Mir1000 FirmwareOperating system
Affected:all versions
Er200 FirmwareOperating system
Affected:all versions
Er Lite FirmwareOperating system
Affected:all versions
Er Flex FirmwareOperating system
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify robot model and firmware version
    Access the robot's web interface or control panel and navigate to System Info or About to retrieve the exact model number and firmware version. Compare against the affected list: Mir100 with firmware <= 2.8.1.1, or any Mir200, Mir250, Mir500, Mir1000, or Easyrobotics Er200, Er Lite, Er Flex.
    Affected if The robot is any Mir100 with firmware 2.8.1.1 or lower, or any Mir200/250/500/1000, or any Easyrobotics model listed.
  2. Locate the default password documentation
    Check the user manual or technical documentation provided with the robot for the documented default password. This is typically found in the safety PLC or robot configuration section of the manual.
    Affected if A default password is documented in publicly available manuals.
  3. Verify if default password is still active
    Attempt to access the safety PLC programming interface or robot administration panel using the documented default password. If authentication succeeds, the default password is still in use.
    Affected if The default password authenticates successfully without being changed.
  4. Check emergency stop function access controls
    Examine the safety PLC program configuration to determine if the emergency stop function can be modified without elevated privileges or additional authentication beyond the default password.
    Affected if The emergency stop function is accessible or modifiable using only the default credentials.
  5. Verify laser scanner configuration protection
    Access the safety system configuration or laser scanner settings through the robot interface and check if changes can be made without strong authentication or are protected by the same default credentials.
    Affected if Laser scanner configuration can be altered using default credentials or is unprotected.

A user is affected if they operate any of the listed robot models, the documented default password is still active, and safety functions (emergency stop, laser scanner) are accessible or modifiable using that default password.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 2.8.1.1
Interim mitigation

Immediately change the default password to a strong, unique password following industrial control system security best practices, and implement proper access control mechanisms to prevent unauthorized changes to safety-critical systems.

Fix this in Mir100 Firmware Scoped from the published advisory
  • Consultation3.0 h
  • Implementation2.0 h
  • Testing3.0 h
  • Review / QA2.0 h
10.0 hours of engineering $1,770
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,832.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2020-10276 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2020-10276 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data