42633 FirmwareOperating system · Lindy International

CVE-2020-15059

HIGH · 8.8 CVSS v3.1 Published 2020-08-07
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
93/100
Remediation priority · Urgent
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Lindy 42633 4-Port USB 2.0 Gigabit Network Server 2.078.000 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

The Lindy 42633 4-Port USB 2.0 Gigabit Network Server firmware version 2.078.000 contains an authentication bypass vulnerability in its web administration interface. An attacker on the same local network can send a crafted HTTP request to the web administration panel that omits the password parameter, bypassing authentication entirely and gaining unauthorized access to device configuration settings.

MitigationRestrict network access to the device's web administration interface via firewall rules or VLAN segmentation to limit exposure to trusted users only. Contact Lindy for firmware updates; if unavailable, consider replacing the device with a model that receives regular security patches.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
42633 FirmwareOperating system
Affected:= 2.078.000

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Locate the physical device or check network inventory for a Lindy 42633 4-Port USB 2.0 Gigabit Network Server. Verify the model number matches exactly.
    Affected if Device is not a Lindy 42633, then it is not affected by this specific CVE.
  2. Check the installed firmware version
    Access the device web administration panel and navigate to the firmware or system information page. Alternatively, check the device documentation or management interface for the firmware version field.
    Affected if Firmware version is not exactly 2.078.000 - only this specific version is affected.
  3. Confirm the web administration interface is enabled
    Attempt to reach the device web interface via HTTP/HTTPS on the configured management port (typically 80 or 443). Verify the login page is accessible.
    Affected if The web interface is not accessible or not enabled, the authentication bypass cannot be exploited.
  4. Verify the device is reachable on the local network
    Ping the device IP address or check network connectivity to confirm the device is online and responding to network requests.
    Affected if The device is not reachable over the network, the attack vector is not present.

The environment is affected only if the device is a Lindy 42633 running firmware version 2.078.000 with its web administration interface enabled and accessible on the network.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict network access to the device's web administration interface via firewall rules or VLAN segmentation to limit exposure to trusted users only. Contact Lindy for firmware updates; if unavailable, consider replacing the device with a model that receives regular security patches.

Fix this in 42633 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation3.0 h
  • Testing2.0 h
  • Review / QA1.0 h
8.0 hours of engineering $1,420
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $2,272.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2020-15059 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2020-15059 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data