CVE-2020-15784

MEDIUM · 5.3 CVSS v3.1 Published 2020-09-09
Fix available
A fix is available. Upgrade to 4.70 or later.
See remediation →
62/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). Insecure storage of sensitive information in the configuration files could allow the retrieval of user names.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Spectrum Power 4 versions before V4.70 SP8 store sensitive information (specifically user names) insecurely in configuration files. This allows an attacker with access to the configuration files to retrieve stored user names, potentially facilitating further attacks such as credential stuffing or social engineering.

MitigationUpgrade to Spectrum Power 4 V4.70 SP8 or later. Additionally, review and remediate any configuration files containing plaintext or weakly protected credentials by implementing proper credential storage mechanisms such as encryption or secure credential vaults.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Spectrum Power 4Application
Affected:< 4.70= 4.70

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Determine the installed Spectrum Power 4 version
    Use the Spectrum Power 4 system information dialog, about menu, or version check command specific to the installation. Common methods include checking the software itself or reviewing installation metadata.
    Affected if The installed version is lower than 4.70 or exactly 4.70 (versions prior to V4.70 SP8 are affected)
  2. Locate Spectrum Power 4 configuration files
    Identify the configuration directory where Spectrum Power 4 stores its settings. This is typically found in the application data folder, installation directory, or system config paths used by the product.
    Affected if Configuration files exist and are accessible to the user (the vulnerability requires access to these files)
  3. Inspect configuration files for plaintext usernames
    Open and examine the configuration files for any entries that contain user names stored in plaintext. Look for fields labeled with user-related terms such as username, user, account, or similar identifiers.
    Affected if Usernames or user account names are found stored in plaintext within configuration files
  4. Check for other sensitive data stored insecurely
    Review configuration files for any other sensitive information stored without encryption or protection, including potential credential-related fields beyond just usernames.
    Affected if Any sensitive information is stored in an insecure manner (the vulnerability specifically mentions usernames but similar insecure storage patterns may exist)

You are affected if your Spectrum Power 4 version is 4.70 or any version below 4.70 AND configuration files contain plaintext usernames that could be retrieved by an attacker with file access.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 4.70 or later
Fixed in 4.70
Interim mitigation

Upgrade to Spectrum Power 4 V4.70 SP8 or later. Additionally, review and remediate any configuration files containing plaintext or weakly protected credentials by implementing proper credential storage mechanisms such as encryption or secure credential vaults.

Fix this in Spectrum Power 4 Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA2.0 h
18.0 hours of engineering $3,200
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,120.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2020-15784 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2020-15784 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data