CVE-2020-1654
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedOn Juniper Networks SRX Series with ICAP (Internet Content Adaptation Protocol) redirect service enabled, processing a malformed HTTP message can lead to a Denial of Service (DoS) or Remote Code Execution (RCE) Continued processing of this malformed HTTP message may result in an extended Denial of Service (DoS) condition. The offending HTTP message that causes this issue may originate both from the HTTP server or the HTTP client. This issue affects Juniper Networks Junos OS on SRX Series: 18.1 versions prior to 18.1R3-S9 ; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S1; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3; 19.1 versions prior to 19.1R1-S5, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2; 19.3 versions prior to 19.3R2. This issue does not affect Juniper Networks Junos OS prior to 18.1R1.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA vulnerability in Juniper Networks SRX Series devices with ICAP (Internet Content Adaptation Protocol) redirect service enabled allows remote attackers to cause Denial of Service or achieve Remote Code Execution by sending malformed HTTP messages. The malformed traffic can originate from either the HTTP server or client side.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 18.1= 18.2= 18.3= 18.4= 19.1= 19.2= 19.3CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify device modelRun 'show chassis hardware' or 'show system information' to confirm the device is a Juniper SRX Series device.Affected if Device is not an SRX Series device (the vulnerability only affects SRX Series).
-
Check Junos OS versionRun 'show version' or 'show system version' to obtain the installed Junos OS version.Affected if The installed version matches one of the affected versions: 18.1, 18.2, 18.3, 18.4, 19.1, 19.2, or 19.3 (any specific release within these major.minor branches).
-
Verify ICAP redirect service configurationRun 'show configuration | display set | match icap' or 'show services icap' to check if ICAP redirect service is configured and enabled.Affected if ICAP redirect service is actively configured on the device (the vulnerability requires ICAP redirect to be enabled).
-
Inspect ICAP redirect policy bindingsRun 'show services icap redirect policy' to see any defined ICAP redirect policies and their status.Affected if ICAP redirect policies exist and are applied (this confirms the attack surface is present).
A device is affected if it is an SRX Series running a vulnerable Junos 18.1-19.3 version AND has ICAP redirect service configured and active.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scopedUpgrade Junos OS to the specified fixed versions (18.1R3-S9, 18.2R2-S7, 18.2R3-S3, 18.3R2-S4, 18.3R3-S1, 18.4R3, 19.1R2, 19.2R2, 19.3R2 or later). If immediate patching is not possible, consider disabling ICAP redirect service if not required.
Upgrade to 18.1R3-S9, 18.2R3-S3, 18.3R3-S1, 18.4R3, or later (19.1R2, 19.2R2, 19.3R2 or later)
- 1. Identify the current Junos OS version on the SRX Series device using 'show version'
- 2. Check if ICAP redirect service is enabled using 'show services icap redirect status' or reviewing the configuration
- 3. If ICAP redirect service is not needed, disable it as a workaround: delete services icap redirect
- 4. If ICAP redirect service is required, plan for upgrade to a fixed version
- 5. Download the appropriate fixed Junos OS release from the Juniper Networks support portal
- 6. Upload the upgrade package to the device
- 7. Install the upgrade using 'request system software add <package>'
- 8. Reboot the device after upgrade using 'request system reboot'
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation6.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,544.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2020-1654 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2020-1654 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data