Server Board S2600wt FirmwareOperating system · Intel

CVE-2020-8730

HIGH · 8.8 CVSS v3.1 Published 2020-08-13
Fix available
A fix is available. Upgrade to 1.59 or later.
See remediation →
90/100
Remediation priority · Urgent
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Heap-based overflow for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an authenticated user to potentially enable escalation of privilege via local access.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A heap-based buffer overflow vulnerability exists in Intel Server Boards, Server Systems, and Compute Modules before version 1.59. The flaw allows an authenticated local user to potentially escalate privileges via heap memory corruption. This is a firmware-level vulnerability affecting Intel server hardware infrastructure.

MitigationUpdate Intel server firmware to version 1.59 or later to remediate the vulnerability. In the interim, limit local access to trusted personnel and monitor for unauthorized access attempts.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Server Board S2600wt FirmwareOperating system
Affected:< 1.59
Server System R1000wt FirmwareOperating system
Affected:< 1.59
Server System R2000wt FirmwareOperating system
Affected:< 1.59
Server Board S2600cwOperating system
Affected:< 1.59
Compute Module Hns2600kp FirmwareOperating system
Affected:< 1.59
Server Board S2600kp FirmwareOperating system
Affected:< 1.59
Compute Module Hns2600tp FirmwareOperating system
Affected:< 1.59
Compute Module S2600tp FirmwareOperating system
Affected:< 1.59

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
Low
User interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the Intel server product model
    Locate the product model label on the server chassis or access the BMC web interface to view system information. Confirm the model is one of: S2600wt, R1000wt, R2000wt, S2600cw, Hns2600kp, S2600kp, Hns2600tp, or S2600tp.
    Affected if The product model matches one of the affected models listed in the CVE.
  2. Retrieve the current firmware version
    Access the BMC (Baseboard Management Controller) web interface or use IPMI commands such as 'ipmitool -I lanplus -H <BMC_IP> -U <user> -P <pass> raw' to query the BMC for firmware revision. Alternatively, check via Intel Server Management software or Intel System Information Viewer.
    Affected if Unable to retrieve firmware version or version data is unavailable.
  3. Compare firmware version to 1.59
    Review the obtained firmware version number against the affected version range. The vulnerability affects versions before 1.59.
    Affected if The installed firmware version is less than 1.59.
  4. Verify local authenticated access exists
    Determine if local user accounts are configured on the BMC or server OS with privileges sufficient to exploit the flaw. Review user access controls and account permissions.
    Affected if Local authenticated user accounts exist on the system and the firmware version is below 1.59.

You are affected if your Intel server product model matches one of the listed affected models AND the installed firmware version is below 1.59 AND local authenticated user access is present.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 1.59 or later
Fixed in 1.59
Interim mitigation

Update Intel server firmware to version 1.59 or later to remediate the vulnerability. In the interim, limit local access to trusted personnel and monitor for unauthorized access attempts.

Fix this in Server Board S2600wt Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA4.0 h
22.0 hours of engineering $3,860
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2020-8730 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2020-8730 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data