Efi Bios 7215Operating system · Intel

CVE-2021-0070

HIGH · 8.8 CVSS v3.1 Published 2021-06-09
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
93/100
Remediation priority · Urgent
No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Improper input validation in the BMC firmware for Intel(R) Server Board M10JNP2SB before version EFI BIOS 7215, BMC 8100.01.08 may allow an unauthenticated user to potentially enable an escalation of privilege via adjacent access.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

This vulnerability in Intel Server Board M10JNP2SB BMC firmware involves improper input validation that allows an unauthenticated attacker with adjacent network access to potentially escalate privileges. The issue affects both EFI BIOS (versions before 7215) and BMC (versions before 8100.01.08) components.

MitigationApply the vendor-provided firmware updates (EFI BIOS 7215 and BMC 8100.01.08 or later) following Intel's recommended update procedures, and restrict physical/adjacent network access to the server infrastructure.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Efi Bios 7215Operating system
Affected:< bmc_8100.01.08

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Intel Server Board M10JNP2SB is in use
    Use IPMI command 'ipmitool chassis status' or access BIOS setup screen to identify the server board model number
    Affected if The system is an Intel Server Board M10JNP2SB
  2. Check EFI BIOS version
    Run 'ipmitool raw' command or view BIOS setup screen to retrieve the EFI BIOS version; compare numerically against version 7215
    Affected if EFI BIOS version is numerically less than 7215
  3. Check BMC firmware version
    Execute 'ipmitool mc info' command or log into BMC web interface to obtain firmware version; compare against 8100.01.08
    Affected if BMC firmware version is earlier than 8100.01.08
  4. Determine BMC network accessibility
    Review network configuration and firewall rules to check if the BMC management interface is exposed to adjacent network segments
    Affected if BMC is reachable from adjacent or untrusted network segments

System is affected if it is an Intel Server Board M10JNP2SB with EFI BIOS version below 7215 OR BMC firmware version below 8100.01.08, especially when the BMC has adjacent network accessibility

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply the vendor-provided firmware updates (EFI BIOS 7215 and BMC 8100.01.08 or later) following Intel's recommended update procedures, and restrict physical/adjacent network access to the server infrastructure.

Recommended fix High confidence

EFI BIOS 7215 and BMC 8100.01.08

  1. 1. Navigate to Intel's support website and download the EFI BIOS version 7215 and BMC firmware version 8100.01.08 for the Intel Server Board M10JNP2SB
  2. 2. Verify the current firmware versions by accessing the BMC web interface or using IPMI commands
  3. 3. Apply the BMC firmware update 8100.01.08 through the BMC web interface, IPMI firmware update command, or Intel System Update Utility
  4. 4. After BMC update completes, apply the EFI BIOS version 7215 update through the BMC web interface, Intel System Update Utility, or BIOS flash utility
  5. 5. Reboot the system to ensure both firmware updates take effect
  6. 6. Verify the installed versions match the target versions (EFI BIOS 7215 and BMC 8100.01.08)

Generated from the published advisory — verify against the referenced sources before acting.

Fix this in Efi Bios 7215 Scoped from the published advisory
  • Consultation4.0 h
  • Implementation3.0 h
  • Testing4.0 h
  • Review / QA2.0 h
13.0 hours of engineering $2,300
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,680.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-0070 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-0070 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data