CVE-2021-0285
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn uncontrolled resource consumption vulnerability in Juniper Networks Junos OS on QFX5000 Series and EX4600 Series switches allows an attacker sending large amounts of legitimate traffic destined to the device to cause Interchassis Control Protocol (ICCP) interruptions, leading to an unstable control connection between the Multi-Chassis Link Aggregation Group (MC-LAG) nodes which can in turn lead to traffic loss. Continued receipt of this amount of traffic will create a sustained Denial of Service (DoS) condition. An indication that the system could be impacted by this issue is the following log message: "DDOS_PROTOCOL_VIOLATION_SET: Warning: Host-bound traffic for protocol/exception LOCALNH:aggregate exceeded its allowed bandwidth at fpc <fpc number> for <n> times, started at <timestamp>" This issue affects Juniper Networks Junos OS on QFX5000 Series and EX4600 Series: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S7; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R1-S1, 20.4R2.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceUncontrolled resource consumption in Junos OS on QFX5000 and EX4600 switches allows attacker-sent large amounts of legitimate traffic to overwhelm the device's rate limiting for host-bound traffic (LOCALNH:aggregate), causing Interchassis Control Protocol (ICCP) interruptions between MC-LAG nodes, leading to unstable control connections and sustained DoS via traffic loss.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 15.1= 17.3= 17.4= 18.3= 18.4= 19.1= 19.2= 19.3= 19.4= 20.1= 20.2= 20.3CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify device modelRun 'show chassis hardware' or check the physical device label to confirm it is a QFX5000 series or EX4600 switchAffected if Device is NOT a QFX5000 or EX4600 model (other models are not affected by this specific vulnerability)
-
Check Junos OS versionRun 'show version' and note the installed Junos version numberAffected if Version matches any of these: 15.1, 17.3, 17.4, 18.3, 18.4, 19.1, 19.2, 19.3, 19.4, 20.1, 20.2, or 20.3
-
Verify ICCP/MC-LAG configurationRun 'show configuration protocols iccp' to check if Interchassis Control Protocol is configured between MC-LAG nodesAffected if ICCP is not configured (the vulnerability specifically impacts ICCP connections between MC-LAG nodes)
-
Check for DDOS_PROTOCOL_VIOLATION_SET log messagesRun 'show log messages | match DDOS_PROTOCOL_VIOLATION_SET' to look for evidence of host-bound traffic exceeding allowed bandwidthAffected if Log messages show host-bound traffic (LOCALNH:aggregate) exceeded configured rate limits
A user is affected if they are running a vulnerable Junos version (15.1, 17.3-17.4, 18.3-18.4, 19.1-19.4, 20.1-20.3) on a QFX5000 or EX4600 switch with ICCP/MC-LAG configured, and they observe DDOS_PROTOCOL_VIOLATION_SET logs indicating rate limit violations for host-bound traffic.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply the appropriate Junos OS patch/upgrade per the Juniper advisory for the affected version. Monitor for DDOS_PROTOCOL_VIOLATION_SET log messages indicating host-bound traffic exceeded allowed bandwidth.
- Consultation6.0 h
- Implementation8.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,760.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2021-0285 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2021-0285 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm