SonicosOperating system · Sonicwall

CVE-2021-20019

HIGH · 7.5 CVSS v3.1 Published 2021-06-23
Fix available
A fix is available. Upgrade to 7.0.0.376 / 7.0.1-r1036 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability in SonicOS where the HTTP server response leaks partial memory by sending a crafted HTTP request, this can potentially lead to an internal sensitive data disclosure vulnerability.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A memory disclosure vulnerability exists in the SonicOS HTTP server component. An unauthenticated remote attacker can send a specially crafted HTTP request to cause the server to leak partial memory contents in its HTTP response, potentially exposing sensitive internal data.

MitigationApply the vendor-supplied SonicOS patch for CVE-2021-20019. If immediate patching is not possible, restrict or block untrusted HTTP access to the affected SonicWall device management interfaces from external networks.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
SonicosOperating system
Affected:>= 7.0.0, < 7.0.0.376>= 7.0.1, < 7.0.1-r1036= 6.0.5.3-94o= 6.5.1.12-3n= 6.5.4.7-83n
SonicosvOperating system
Affected:= 6.5.4.4-44v-21-955

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the SonicOS version
    Access the device management interface and navigate to System > Status or use the CLI command 'show version' to display the installed SonicOS version and build number
    Affected if The displayed version falls within any of these ranges: 7.0.0 through 7.0.0.375, 7.0.1 through 7.0.1-r1035, exactly 6.0.5.3-94o, exactly 6.5.1.12-3n, exactly 6.5.4.7-83n, or exactly 6.5.4.4-44v-21-955 (Sonicosv)
  2. Verify HTTP management interface is enabled
    Check the device network settings to confirm the HTTP server component is listening on any accessible interface. In the management GUI, go to Network > Interfaces and verify HTTP management is enabled on the relevant zone or interface
    Affected if HTTP management interface is enabled and reachable on the device
  3. Check if HTTP is exposed to untrusted networks
    Review firewall access rules and interface bindings to determine if the SonicWall management HTTP port (typically port 80 or 443) is exposed to external or untrusted networks rather than being restricted to trusted management networks
    Affected if The HTTP management interface is accessible from external or untrusted network segments

The device is affected if it runs any SonicOS version within the vulnerable ranges listed and has its HTTP management interface exposed, making it possible for an unauthenticated attacker to send crafted requests that leak memory contents.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 7.0.0.376 / 7.0.1-r1036 or later
Fixed in 7.0.0.3767.0.1-r1036
Interim mitigation

Apply the vendor-supplied SonicOS patch for CVE-2021-20019. If immediate patching is not possible, restrict or block untrusted HTTP access to the affected SonicWall device management interfaces from external networks.

Fix this in Sonicos Scoped from the published advisory
  • Consultation2.0 h
  • Implementation1.0 h
  • Testing2.0 h
  • Review / QA1.0 h
6.0 hours of engineering $1,060
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,696.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-20019 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-20019 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data