Poweredge R640 FirmwareOperating system · Dell

CVE-2021-21556

MEDIUM · 6.7 CVSS v3.1 Published 2021-06-14
Fix available
A fix is available. Upgrade to 2.11.2 or later.
See remediation →
69/100
Remediation priority · Elevated
Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a stack-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

Stack-based buffer overflow vulnerability in Dell PowerEdge BIOS (R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, T640) specifically triggered when NVDIMM-N memory modules are installed. Local high-privileged attacker can exploit this to execute arbitrary code, cause DoS, or disclose information within the UEFI/BIOS Preboot Environment.

MitigationApply Dell-provided BIOS/firmware updates for affected PowerEdge models. Organizations should identify systems with NVDIMM-N installed and prioritize patching, as this is a firmware-level vulnerability requiring BIOS update rather than software patching.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Poweredge R640 FirmwareOperating system
Affected:< 2.11.2
Poweredge R740 FirmwareOperating system
Affected:< 2.11.2
Poweredge R740xd FirmwareOperating system
Affected:< 2.11.2
Poweredge R940 FirmwareOperating system
Affected:< 2.11.2
Poweredge R840 FirmwareOperating system
Affected:< 2.11.2
Poweredge R940xa FirmwareOperating system
Affected:< 2.11.2
Poweredge T640 FirmwareOperating system
Affected:< 2.11.2
Poweredge Mx740c FirmwareOperating system
Affected:< 2.11.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Local
Complexity
Low
Privileges
High
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify your PowerEdge server model
    Use iDRAC web interface, iDRAC command line (racadm), or check the system service tag label on the chassis to confirm the exact model (R640, R740, R740xd, R840, R940, R940xa, T640, MX740c, or MX840c)
    Affected if The server model is one of the affected models listed in the CVE (R640, R740, R740xd, R840, R940, R940xa, T640, MX740c, MX840c)
  2. Check the installed BIOS/firmware version
    Access iDRAC web interface under Firmware Inventory, or run 'racadm get BIOS.BiosBootSettings' via iDRAC command line, or view firmware version displayed during POST or in BIOS setup under Firmware Revision
    Affected if The firmware version is lower than 2.11.2 (for example, 2.8.0, 2.10.1, etc.)
  3. Verify if NVDIMM-N memory modules are installed
    Check physical DIMM slots for NVDIMM-N modules (look for NVDIMM-N branded modules), or query via iDRAC under Memory Inventory, or run 'racadm get Memory' to list all memory devices and their types
    Affected if NVDIMM-N modules are physically present in the server (the vulnerability only triggers when these specific NVDIMM-N modules are installed)

You are affected if your server is one of the listed PowerEdge models, has NVDIMM-N memory installed, and runs BIOS firmware version below 2.11.2; all three conditions must be true.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to 2.11.2 or later
Fixed in 2.11.2
Interim mitigation

Apply Dell-provided BIOS/firmware updates for affected PowerEdge models. Organizations should identify systems with NVDIMM-N installed and prioritize patching, as this is a firmware-level vulnerability requiring BIOS update rather than software patching.

Fix this in Poweredge R640 Firmware Scoped from the published advisory
  • Consultation2.0 h
  • Implementation4.0 h
  • Testing4.0 h
  • Review / QA2.0 h
12.0 hours of engineering $2,080
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,328.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-21556 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-21556 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data