Evc1s22p4 FirmwareOperating system · Schneider Electric

CVE-2021-22725

HIGH · 8.8 CVSS v3.1 Published 2022-01-28
Fix available
A fix is available. Upgrade to 3.4.0.2 or later.
See remediation →
95/100
Remediation priority · Urgent
Remotely reachable No privileges Patch available

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis
How this class of weakness works · CWE-352

The application can't tell whether a state-changing request was genuinely intended by the user, so an attacker can trick a logged-in victim's browser into making it. That can transfer funds, change settings, or create accounts silently. Remediation is anti-CSRF tokens — or equivalent same-site protections — on every state-changing request.

General guidance for the cross-site request forgery (csrf) class — the official description and references above are authoritative for this specific CVE. Want a bespoke review and a reviewed fix? Ask our team →

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Evc1s22p4 FirmwareOperating system
Affected:< 3.4.0.2
Evc1s7p4 FirmwareOperating system
Affected:< 3.4.0.2
Evw2 FirmwareOperating system
Affected:< 3.4.0.2
Evf2 FirmwareOperating system
Affected:< 3.4.0.2
Evp2pe FirmwareOperating system
Affected:< 3.4.0.2
Evb1a FirmwareOperating system
Affected:< 3.4.0.2

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 3.4.0.2 or later
Fixed in 3.4.0.2
Recommended fix High confidence

R8 V3.4.0.2 (or later)

  1. 1. Identify the specific EVlink charging station model (EVC1S22P4, EVC1S7P4, EVW2, EVF2, EVP2PE, or EVB1A) currently deployed
  2. 2. Check the current firmware version of the charging station through its web interface or management system
  3. 3. Navigate to the Schneider Electric download portal at https://download.schneider-electric.com/ and locate the firmware update for your specific model
  4. 4. Download firmware version R8 V3.4.0.2 or later for your EVlink product
  5. 5. Follow Schneider Electric's official firmware upgrade procedure documented in the product manual
  6. 6. After upgrading, verify the new firmware version is 3.4.0.2 or higher
  7. 7. Confirm the web server now implements CSRF protection (anti-CSRF tokens) for POST requests
Caveat Firmware upgrades on industrial/IoT devices may require downtime and should be tested in a staging environment first; review release notes for any functionality changes

Generated from the published advisory — verify against the referenced sources before acting.

We can perform the upgrade in your staging environment and verify nothing breaks — typical engagement from $1,950. Get the upgrade done

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-22725 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-22725 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data