Spacelynk FirmwareOperating system · Schneider Electric

CVE-2021-22739

MEDIUM · 5.9 CVSS v3.1 Published 2021-05-26
Fix available
A fix is available. Upgrade to after 2.6.0 or later.
See remediation →
68/100
Remediation priority · Elevated
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

Information Exposure vulnerability in Schneider Electric homeLYnk and spaceLYnk building automation controllers (V2.60 and prior) allows potential device compromise during initial configuration, likely through exposure of sensitive credentials or configuration data.

MitigationUpgrade to a patched version beyond V2.60 and ensure initial device configuration occurs on isolated, trusted networks to prevent information interception during setup.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Spacelynk FirmwareOperating system
Affected:<= 2.6.0
Homelynk FirmwareOperating system
Affected:<= 2.6.0

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
High
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Check device firmware version
    Access the device web interface or use the device's system information page to identify the currently installed firmware version. Compare this to the affected version range of <= 2.6.0.
    Affected if The installed firmware version is 2.6.0 or prior.
  2. Identify device model
    Confirm whether the device is a Schneider Electric spaceLYnk or homeLYnk controller by checking the device label, web interface, or system information.
    Affected if The device is a spaceLYnk or homeLYnk model running firmware <= 2.6.0.
  3. Assess configuration state
    Determine whether initial device configuration has been completed or is currently in progress, as the vulnerability relates to information exposure during this phase.
    Affected if The device is running <= 2.6.0 and initial configuration has been performed or is ongoing.

The device is affected if it is a Schneider Electric spaceLYnk or homeLYnk controller running firmware version 2.6.0 or prior.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Upgrade available Upgrade to a release after 2.6.0
Interim mitigation

Upgrade to a patched version beyond V2.60 and ensure initial device configuration occurs on isolated, trusted networks to prevent information interception during setup.

Fix this in Spacelynk Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing6.0 h
  • Review / QA2.0 h
20.0 hours of engineering $3,500
Get the upgrade done

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-22739 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-22739 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data