Connexium Network ManagerApplication · Schneider Electric

CVE-2021-22801

CRITICAL · 9.8 CVSS v3.1 Published 2022-02-11
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
100/100
Remediation priority · Urgent
Remotely reachable No privileges Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

A CWE-269 Improper Privilege Management vulnerability in ConneXium Network Manager Software allows arbitrary command execution through specially crafted event actions. The software fails to properly validate or restrict privileges when processing event action configurations, enabling an attacker to execute commands with elevated privileges.

MitigationRestrict administrative access to the event action configuration interface, implement strict input validation on all event action parameters, and apply network segmentation. Contact Schneider Electric for patch availability.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Connexium Network ManagerApplication
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify if ConneXium Network Manager is installed
    Look for the software in system registry (HKLM\SOFTWARE\Schneider Electric\ConneXium Network Manager), check for installation directory (typically C:\Program Files\Schneider Electric\ConneXium or similar), or check running processes for CNM-related executables
    Affected if The software is present on the system
  2. Locate the event action configuration interface
    Search for configuration files, management console, or web interface related to event actions - typically found in the software's management console under Event/Alarm configuration sections
    Affected if Event action configuration functionality exists in the installation
  3. Verify access to the event action configuration
    Check if the user account accessing the system has administrative or elevated privileges to configure event actions - inspect user permissions on the management interface or configuration directories
    Affected if Users with administrative or elevated privileges can access the event action configuration interface
  4. Inspect event action configuration files or logs
    Examine configuration files in the software's data directory for event action definitions, looking for parameters that accept command strings or executable paths
    Affected if Event action configurations can be modified or created with user-supplied values

If ConneXium Network Manager is installed and the event action configuration interface is accessible to users with elevated privileges, the environment is affected by CVE-2021-22801.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Restrict administrative access to the event action configuration interface, implement strict input validation on all event action parameters, and apply network segmentation. Contact Schneider Electric for patch availability.

Fix this in Connexium Network Manager Scoped from the published advisory
  • Consultation4.0 h
  • Implementation16.0 h
  • Testing8.0 h
  • Review / QA4.0 h
32.0 hours of engineering $5,600
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $8,960.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-22801 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-22801 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data