CVE-2021-22825
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceThis is a CWE-200 vulnerability in APC network management card (NMC) firmware where a malicious URL can compromise a security token when clicked by a privileged user, allowing unauthorized access with elevated privileges. The vulnerability affects NMC2 firmware versions 6.9.6 and earlier on AP7xxxx/AP8xxx models, and NMC3 firmware versions 1.1.0.3/1.0.0.28 and earlier on AP7xxx/AP8xxx and APDU9xxx models.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 7.0.6< 1.2.0.2CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- Low
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the NMC device type and modelAccess the NMC web interface or SSH console and locate the device model information (AP7xxx, AP8xxx, or APDU9xxx) and confirm whether it uses NMC2 or NMC3 firmware. This is typically visible on the login page, dashboard, or via the 'about' command in SSH.Affected if Device is an AP7xxx/AP8xxx with NMC2, or an AP7xxx/AP8xxx/APDU9xxx with NMC3 - only these models and NMC types are affected.
-
Determine the installed NMC2 firmware versionIf the device has NMC2, check the firmware version in the web interface under System > About or via SSH using the 'version' or 'about' command. Look for a version number.Affected if The version is 7.0.6 or lower, or 6.9.6 or earlier per the CVE description.
-
Determine the installed NMC3 firmware versionIf the device has NMC3, check the firmware version in the web interface under System > About or via SSH using the 'version' or 'about' command. Look for a version number.Affected if The version is 1.2.0.2 or lower, or specifically 1.1.0.3/1.0.0.28 or earlier per the CVE description.
-
Verify if privileged users exist who could click malicious URLsReview user accounts in the NMC interface under User Management or Access Control. Identify accounts with administrative or privileged access rights.Affected if Privileged user accounts exist - the exploitation requires a privileged user to click a maliciously crafted URL.
A user is affected if they have an APC NMC2 or NMC3 device with firmware version below 7.0.6 (NMC2) or below 1.2.0.2 (NMC3), and there are privileged users who could potentially click a malicious URL.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped1.2.0.27.0.6
Update NMC2 firmware to version 6.9.7 or later and NMC3 firmware to version 1.1.0.4/1.0.0.29 or later. Until patched, educate privileged users to avoid clicking untrusted URLs and consider network segmentation to limit exposure.
Rack PDU with NMC2: upgrade to firmware 7.0.6 or later; Rack PDU with NMC3: upgrade to firmware 1.2.0.2 or later
- Identify the exact model number (AP7xxx, AP8xxx, or APDU9xxx) and current NMC firmware version of the Rack PDU
- Navigate to Schneider Electric's support portal at download.schneider-electric.com
- Locate the firmware update for your specific PDU model and NMC version
- Download the appropriate firmware: NMC2 upgrade to version 7.0.6 or later, NMC3 upgrade to version 1.2.0.2 or later
- Review Schneider Electric's firmware installation guide for your specific PDU model
- Apply the firmware update following the vendor's documented upgrade procedure
- After reboot, verify the firmware has been updated to the fixed version (NMC2: 7.0.6+ or NMC3: 1.2.0.2+)
- Confirm the vulnerability is resolved by reviewing the security release notes
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,600.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2021-22825 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2021-22825 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data