Siprotec 5 With Cpu Variant Cp050Operating system · Siemens

CVE-2021-33720

HIGH · 7.5 CVSS v3.1 Published 2021-09-14
Fix available
A fix is available. Upgrade to 8.80 or later.
See remediation →
84/100
Remediation priority · High
Remotely reachable No privileges Zero-click Patch available

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis
How this class of weakness works · CWE-120

A fixed-size buffer is filled without checking the length of the incoming data, so it overflows into neighbouring memory. This is the classic overflow attackers use to overwrite return addresses and hijack execution. The fix is strict length checks and safe, bounded string and memory functions.

General guidance for the classic buffer overflow class — the official description and references above are authoritative for this specific CVE. Want a bespoke review and a reviewed fix? Ask our team →

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Siprotec 5 With Cpu Variant Cp050Operating system
Affected:< 8.80
Siprotec 5 With Cpu Variant Cp100Operating system
Affected:< 8.80
Siprotec 5 With Cpu Variant Cp300Operating system
Affected:< 8.80

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 8.80 or later
Fixed in 8.80
Recommended fix High confidence

SIPROTEC 5 V8.80 (for CPU variants CP050, CP100, CP300)

  1. Contact Siemens support or visit the Siemens product certification portal to obtain the V8.80 firmware update
  2. Obtain the appropriate firmware for your specific CPU variant (CP050, CP100, or CP300)
  3. Follow Siemens standard firmware upgrade procedures for SIPROTEC 5 devices - typically performed via the device's web interface on port 4443/tcp or through the engineering software
  4. After upgrade, verify the firmware version is V8.80 or later
  5. Confirm the device is functioning normally and the service on port 4443/tcp is operational

Generated from the published advisory — verify against the referenced sources before acting.

We can perform the upgrade in your staging environment and verify nothing breaks — typical engagement from $3,200. Get the upgrade done

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-33720 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-33720 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data