Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedAn issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceInsydeH2O UEFI firmware contains an SMM memory corruption vulnerability in the FvbServicesRuntimeDxe driver across multiple kernel versions. An attacker can write fixed or predictable data to SMRAM (System Management RAM), potentially achieving arbitrary code execution at the highest CPU privilege level (SMM), which enables persistent firmware-level compromise.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data>= 5.0, < 5.08.42>= 5.1, < 5.16.42>= 5.2, < 5.26.42>= 5.3, < 5.35.42>= 5.4, < 5.42.51>= 5.5, < 5.50.51all versionsall versionsall versionsall versionsall versionsall versionsall versionsCVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- High
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify UEFI firmware versionRun 'dmidecode -s bios-version' or use manufacturer-provided tools (e.g., 'biosinfo' on Windows, 'fwupdtool get-vars' or UEFI shell 'dmidecode') to retrieve the installed UEFI firmware versionAffected if The displayed version falls within the affected ranges: for Kernel 5.0: < 05.08.42; Kernel 5.1: < 05.16.42; Kernel 5.2: < 05.26.42; Kernel 5.3: < 05.35.42; Kernel 5.4: < 05.42.51; Kernel 5.5: < 05.50.51, or is an unpatched Siemens device firmware version
-
Determine InsydeH2O kernel versionUse UEFI shell 'dmidecode -t 0' or check manufacturer documentation; some systems expose the firmware kernel version via 'fwupdtool get-vars' or by reading the UEFI setup screen for the firmware revision string which may contain a kernel identifierAffected if The kernel version shown is 5.0, 5.1, 5.2, 5.3, 5.4, or 5.5 and the corresponding version number is below the fixed versions listed in the CVE
-
Verify FvbServicesRuntimeDxe driver presenceFrom UEFI shell, run 'drivers' or use 'efimgr' tool to list loaded UEFI drivers; look for FvbServicesRuntimeDxe in the driver listAffected if The FvbServicesRuntimeDxe driver is listed as loaded or present in the firmware image
-
Identify Siemens device model and firmware versionFor Siemens Simatic devices (Field Pg M5/M6, Ipc127e, Ipc227g, Ipc277g, Ipc327g, Ipc377g), use the device's web interface, SIMATIC IPC Manager, or manufacturer firmware update tool to retrieve the installed firmware versionAffected if The device is any of the listed Siemens models running any firmware version, as all versions of these products are affected according to the CVE
You are affected if your InsydeH2O firmware kernel version falls within the specified vulnerable ranges and is below the fixed versions, or if your device is one of the listed Siemens models running any firmware version.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped5.08.425.16.425.26.42
Update InsydeH2O UEFI firmware to version 05.08.42 or later for Kernel 5.0, 05.16.42 or later for Kernel 5.1, 05.26.42 or later for Kernel 5.2, 05.35.42 or later for Kernel 5.3, 05.42.51 or later for Kernel 5.4, or 05.50.51 or later for Kernel 5.5, per vendor guidance.
InsydeH2O Kernel 5.0 to 05.08.42+; Kernel 5.1 to 05.16.42+; Kernel 5.2 to 05.26.42+; Kernel 5.3 to 05.35.42+; Kernel 5.4 to 05.42.51+; Kernel 5.5 to 05.50.51+ | Simatic products: Contact Siemens for specific patched firmware
- 1. Identify the InsydeH2O kernel version running on the affected device by checking the UEFI/BIOS firmware version information.
- 2. For InsydeH2O devices: Upgrade to the appropriate fixed kernel version: Kernel 5.0 to 05.08.42 or later; Kernel 5.1 to 05.16.42 or later; Kernel 5.2 to 05.26.42 or later; Kernel 5.3 to 05.35.42 or later; Kernel 5.4 to 05.42.51 or later; Kernel 5.5 to 05.50.51 or later.
- 3. Obtain the firmware update from the device manufacturer (OEM) - InsydeH2O is a framework used by multiple OEMs, so obtain the update through the OEM's support channels.
- 4. For Siemens Simatic products (Field Pg M5/M6, IPC127e, IPC227g, IPC277g, IPC327g, IPC377g): Contact Siemens customer support or visit the Siemens industrial security portal to obtain patched firmware. These products list all versions as affected, indicating specific patch availability must be confirmed with Siemens.
- 5. Apply the firmware update following the OEM's documented firmware flashing procedure, ensuring power stability during the update process.
- 6. Verify the firmware version after update to confirm the patch has been successfully applied.
Generated from the published advisory — verify against the referenced sources before acting.
- Consultation4.0 h
- Implementation8.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,176.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2021-42554 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2021-42554 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data