Cbr750 FirmwareOperating system · Netgear

CVE-2021-45633

HIGH · 8.8 CVSS v3.1 Published 2021-12-26
Fix available
A fix is available. Upgrade to 3.2.17.12 / 4.6.3.6 or later.
See remediation →
93/100
Remediation priority · Urgent
No privileges Zero-click Patch available

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis
How this class of weakness works · CWE-77

User input reaches a command interpreter without being fully separated from the command itself, so an attacker can append instructions of their own. Because those run with the application's privileges, it frequently means control of the host. The lasting fix is to avoid constructing commands from input — call APIs directly and pass arguments as data, never as concatenated strings.

General guidance for the command injection class — the official description and references above are authoritative for this specific CVE. Want a bespoke review and a reviewed fix? Ask our team →

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Cbr750 FirmwareOperating system
Affected:< 4.6.3.6
Rbk752 FirmwareOperating system
Affected:< 3.2.17.12
Rbr750 FirmwareOperating system
Affected:< 3.2.17.12
Rbs750 FirmwareOperating system
Affected:< 3.2.17.12
Rbk852 FirmwareOperating system
Affected:< 3.2.17.12
Rbr850 FirmwareOperating system
Affected:< 3.2.17.12
Rbs850 FirmwareOperating system
Affected:< 3.2.17.12

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Adjacent
Complexity
Low
Privileges
None
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

dbcve · scoped
Upgrade available Upgrade to 3.2.17.12 / 4.6.3.6 or later
Fixed in 3.2.17.124.6.3.6
Vendor patch kb.netgear.com →
Recommended fix High confidence

CBR750: Firmware 4.6.3.6 | RBR750/RBR850/RBS750/RBS850/RBK752/RBK852: Firmware 3.2.17.12

  1. 1. Identify the specific NETGEAR device model from the affected list (CBR750, RBR750, RBR850, RBS750, RBS850, RBK752, or RBK852)
  2. 2. Access the device administration interface or NETGEAR Genie app
  3. 3. Navigate to the firmware update section (typically under Administration > Firmware Update)
  4. 4. Check the current firmware version to confirm it is vulnerable (below 4.6.3.6 for CBR750, or below 3.2.17.12 for all other models)
  5. 5. Download the latest firmware from the official NETGEAR support site for your specific model
  6. 6. Upload and install the firmware update via the web interface or mobile app
  7. 7. After the device reboots, verify the firmware version has been updated to the fixed release
  8. 8. Confirm the vulnerability is remediated by reviewing the NETGEAR security advisory PSV-2020-0514
Caveat Standard firmware update; ensure stable power during upgrade to avoid device bricking

Generated from the published advisory — verify against the referenced sources before acting.

We can perform the upgrade in your staging environment and verify nothing breaks — typical engagement from $3,200. Get the upgrade done

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2021-45633 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2021-45633 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data