CVE-2021-45640
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedCertain NETGEAR devices are affected by incorrect configuration of security settings. This affects D3600 before 1.0.0.72, D6000 before 1.0.0.72, D6200 before 1.1.00.34, D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000 before 1.0.1.74, D7000v2 before 1.0.0.53, D7800 before 1.0.1.56, D8500 before 1.0.3.44, DC112A before 1.0.0.42, DGN2200v4 before 1.0.0.110, DGND2200Bv4 before 1.0.0.109, DM200 before 1.0.0.61, EX3700 before 1.0.0.76, EX3800 before 1.0.0.76, EX6120 before 1.0.0.46, EX6130 before 1.0.0.28, EX7000 before 1.0.1.78, PR2000 before 1.0.0.28, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.34, R6300v2 before 1.0.4.34, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v3 before 1.0.2.66, R6900 before 1.0.2.6, R7000 before 1.0.9.34, R7100LG before 1.0.0.50, R7500v2 before 1.0.3.40, R7900P before 1.4.1.50, R8000P before 1.4.1.50, R8900 before 1.0.4.12, R9000 before 1.0.4.12, RBK20 before 2.3.0.28, RBK40 before 2.3.0.28, RBK50 before 2.3.0.32, RBR20 before 2.3.0.28, RBR40 before 2.3.0.28, RBR50 before 2.3.0.32, RBS20 before 2.3.0.28, RBS40 before 2.3.0.28, RBS50 before 2.3.0.32, WN3000RPv2 before 1.0.0.78, WNDR3400v3 before 1.0.1.24, WNR2000v5 before 1.0.0.70, WNR2020 before 1.1.0.62, WNR3500Lv2 before 1.2.0.62, XR450 before 2.3.2.56, and XR500 before 2.3.2.56.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysisA detailed technical summary for this CVE is being prepared.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data< 1.0.0.72< 1.0.0.72< 1.1.00.34< 1.0.0.52< 1.0.0.86< 1.0.1.74< 1.0.0.53< 1.0.1.56CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- High
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
dbcve · scoped1.0.0.521.0.0.531.0.0.72
Firmware >= 1.0.0.72 (D3600/D6000), >= 1.1.00.34 (D6200), >= 1.0.0.52 (D6220), >= 1.0.0.86 (D6400), >= 1.0.1.74 (D7000), >= 1.0.0.53 (D7000v2), >= 1.0.1.56 (D7800)
- Identify the exact model number of your NETGEAR device from the product label or web interface
- Navigate to the NETGEAR support website (support.netgear.com) or use the NETGEAR Nighthawk/Orbi app
- Enter your device model number to access its support page
- Locate the firmware download section and check the current installed version (typically in Settings > Advanced > Administration > Firmware Update)
- Download the firmware version equal to or newer than the fixed version for your model: D3600/D6000: 1.0.0.72, D6200: 1.1.00.34, D6220: 1.0.0.52, D6400: 1.0.0.86, D7000: 1.0.1.74, D7000v2: 1.0.0.53, D7800: 1.0.1.56
- Upload and apply the firmware file through the router's web interface (Settings > Advanced > Administration > Firmware Update > Upload)
- Wait for the device to reboot (do not power off during the update process)
- Verify the new firmware version is installed and confirm the security settings are properly configured
Generated from the published advisory — verify against the referenced sources before acting.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2021-45640 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2021-45640 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data