Iot Control CenterApplication · Cisco

CVE-2022-20916

MEDIUM · 6.1 CVSS v3.1 Published 2022-07-22
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
68/100
Remediation priority · Elevated
Remotely reachable No privileges

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
A vulnerability in the web-based management interface of Cisco IoT Control Center could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · high confidence

A stored cross-site scripting (XSS) vulnerability in Cisco IoT Control Center's web-based management interface allows unauthenticated remote attackers to inject malicious scripts via improperly validated user input. Successful exploitation enables arbitrary script execution in the context of the affected interface or access to sensitive browser-based information.

MitigationApply vendor-provided patches for CVE-2022-20916; until patches are available, implement input validation and output encoding on all user-supplied fields in the web interface and educate users about avoiding clicks on untrusted links.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Iot Control CenterApplication
Affected:all versions

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
None
User interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Confirm Cisco IoT Control Center deployment
    Identify if Cisco IoT Control Center is installed in your environment by checking for the product through inventory systems, running processes, or service listings on relevant hosts
    Affected if The product is present in your environment
  2. Check web management interface accessibility
    Determine if the Cisco IoT Control Center web-based management interface is reachable by accessing the management URL (typically on ports 443, 8443, or configured custom ports) from your network
    Affected if The web interface is accessible and responds
  3. Identify input acceptance points
    Locate user input fields in the web management interface such as device names, user profiles, configuration parameters, or any forms accepting user-supplied data
    Affected if The interface contains user input fields that accept data without visible sanitization indicators
  4. Verify unauthenticated input capability
    Test whether the identified input fields can be accessed and used without authentication credentials, as the CVE allows unauthenticated attackers to inject scripts
    Affected if Input fields are accessible to unauthenticated users

If Cisco IoT Control Center is deployed with its web-based management interface accessible and accepting unauthenticated user input, your environment is affected by CVE-2022-20916

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor-provided patches for CVE-2022-20916; until patches are available, implement input validation and output encoding on all user-supplied fields in the web interface and educate users about avoiding clicks on untrusted links.

Fix this in Iot Control Center Scoped from the published advisory
  • Consultation4.0 h
  • Implementation8.0 h
  • Testing4.0 h
  • Review / QA3.0 h
19.0 hours of engineering $3,380
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $5,408.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2022-20916 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2022-20916 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data